Results 1 to 10 of about 169 (151)

New Adaptive Reclosing Technique in Unbalanced Distribution System [PDF]

open access: yesEnergies, 2017
The conventional reclosing of a distribution system is performed after a fixed dead time. However, it may lead to the increased outage time due to delayed reclosing. To solve this problem, this paper proposes a new adaptive reclosing scheme.
Hun-Chul Seo
doaj   +4 more sources

An adaptive reclosing scheme for flexible DC grid based on residual voltage S-transformation [PDF]

open access: yesScientific Reports
When a fault occurs on a line, it is necessary to quickly isolate the fault to improve the safety and reliability of the transmission system. Due to the lack of effective ability to identify the nature of faults, the traditional automatic reclosing ...
Yue Dai   +4 more
doaj   +4 more sources

A Current-Commutation DC Circuit Breaker with Adaptive Reclosing Capability [PDF]

open access: yesE3S Web of Conferences, 2021
DC faults are critical events in a flexible high-voltage dc (HVDC) grid. Thus, ensuring that the power system returns to normal operation rapidly and reliably after fault isolation is very important. This requires a HVDC breaker. In overhead line systems
Jiang Chunbing, Zhao Chengyong
doaj   +2 more sources

Unscented-Kalman-filter-based single-phase adaptive reclosing of shunt-compensated extra-high-voltage transmission lines

open access: yesAlexandria Engineering Journal, 2022
This paper proposes a novel two-stage adaptive reclosing mechanism for shunt-compensated extra-high-voltage transmission lines. In the first stage, secondary arc extinction peak-based criterion (SAEPC) is established to monitor the precise instant of ...
Muhammad Saad, Chul-Hwan Kim
doaj   +3 more sources

A coupling voltage based adaptive reclosing scheme for flexible DC grid

open access: yesIET Generation, Transmission & Distribution, 2023
The total electric field around the DC line is composed of both the ion flow field produced by coronae and the electrostatic field produced by the conductor charge.
Xiuyan Wei   +3 more
doaj   +2 more sources

Adaptive Single-Pole Auto-Reclosing Scheme Based on Secondary Arc Voltage Harmonic Signatures

open access: yesEnergies, 2021
This paper presents an advanced adaptive single-pole auto-reclosing (ASPAR) scheme based on harmonic characteristics of the secondary arc voltage. For analysis of the harmonics, short-time Fourier transform (STFT), which is a universal signal processing ...
Joon Han, Chul-Moon Lee, Chul-Hwan Kim
doaj   +3 more sources

An adaptive single-phase reclosing of line in the scheme with intermediate system [PDF]

open access: yesE3S Web of Conferences, 2019
Providing the reliability of adaptive single-phase reclosing (ASPR) in line equipped with any number of shunt reactors (SR), including the case of their absence, are considered and analyzed in this paper. The essence of the proposed work is that in order
Samorodov German   +2 more
doaj   +2 more sources

An Adaptive Reclosing Strategy for MMC-HVDC Systems With Hybrid DC Circuit Breakers [PDF]

open access: yesIEEE Transactions on Power Delivery, 2020
Modular multilevel converter (MMC) based high voltage direct current transmission (HVDC) is an effective solution for large-scale renewable power integration over long-distance. In the overhead MMC-HVDC systems, the high voltage DC circuit breakers (DCCB) are implemented to interrupt the DC fault current.
Jinyu Wen, Wenping Zuo, Wang Xiang
exaly   +4 more sources

Adaptive Reclosing Technique Using Variational Mode Decomposition Algorithm in BESS-Based Microgrid

open access: yesIEEE Access, 2023
This study introduces a novel adaptive technique to accelerate the process of reclosing in a Battery Energy Storage System (BESS)-based microgrid system to provide uninterrupted power supply (UPS).
Ruchi Chandrakar   +5 more
doaj   +2 more sources

Implementation and performance evaluation of a harmonic filter for use in adaptive single‐phase reclosing

open access: yesIET Generation, Transmission and Distribution, 2017
This study presents an adaptive single‐phase reclosing method based on voltage harmonic measurement implemented in a digital harmonic filter. This filter and the transmission system were modelled in a real‐time digital simulator. A distance relay was used for protection and reclosing, responding as if it was in field operation.
Ozenir Dias, Maria Cristina Tavares
exaly   +2 more sources

Home - About - Disclaimer - Privacy