Space Plasma Distribution Effect of Short-Circuit Arc on Generation of Secondary Arc [PDF]
Secondary arc is more severe in the ultra-high voltage (UHV) power grid. However, the mechanism for the generation process of secondary arc at the extinction moment of a short-circuit arc is not yet clear.
Haoxi Cong +4 more
doaj +4 more sources
A Study on the Transient of Secondary Arc Current of UHV Transmission Lines
Secondary arcs are a type of alternating-current electric arc burning in open space, the arcing times of which are closely related to the transient of their currents.
Qiuqin Sun +4 more
doaj +4 more sources
Modeling Study of the Secondary Arc With Stochastic Initial Positions Caused by the Primary Arc [PDF]
In the conversion process from primary arc to secondary arc, there exists stochasticness phenomenon of the initial positions of secondary arc. However, the present simulation results of the arcing time with the arc chain model are constant, which is not consistent with the test results.
Haoxi Cong, Qingmin Li
exaly +2 more sources
Electric arc furnace transformer secondary circuit calculations [PDF]
This paper demonstrates a procedure for calculating stress and temperature in the secondary high current circuit of a modern electric arc furnace. At the beginning, the separate parameters that form the electric circuit from the furnace to the ...
Cundeva Snezana, Digalovski Mihail
doaj +2 more sources
A Practical Method for Calculating the Reclosing Time in Long Lines with Reactors Case Study: Transmission Lines of Yazd Province [PDF]
In transmission networks, the recloser is used to detect and interrupt transient faults, isolate faults, manage the network structure, and increase reliability.
hossein dehghan dehnavi
doaj +1 more source
Pattern Recognition Based Auto-Reclosing Scheme Using Bi-Directional Long Short-Term Memory Network
Precise knowledge of secondary arc extinction instant and fault nature (temporary or permanent) is necessary for auto-reclosing after a single line-to-ground fault.
Muhammad Saad +2 more
doaj +1 more source
Adaptive Single-Pole Auto-Reclosing Scheme Based on Secondary Arc Voltage Harmonic Signatures
This paper presents an advanced adaptive single-pole auto-reclosing (ASPAR) scheme based on harmonic characteristics of the secondary arc voltage. For analysis of the harmonics, short-time Fourier transform (STFT), which is a universal signal processing ...
Joon Han, Chul-Moon Lee, Chul-Hwan Kim
doaj +1 more source
Arc ubiquitination regulates endoplasmic reticulum-mediated Ca2+ release and CaMKII signaling
Synaptic plasticity relies on rapid, yet spatially precise signaling to alter synaptic strength. Arc is a brain enriched protein that is rapidly expressed during learning-related behaviors and is essential for regulating metabotropic glutamate receptor ...
Mohammad A. Ghane +14 more
doaj +1 more source
This review aims to show the significance of the use of secondary carbon bio-carriers for iron and steel production. The term ‘secondary carbon bio-carriers’ in this review paper refers to biomass, torrefied biomass, biochar, charcoal, or biocoke.
Lina Kieush +11 more
doaj +1 more source
This paper proposes a novel two-stage adaptive reclosing mechanism for shunt-compensated extra-high-voltage transmission lines. In the first stage, secondary arc extinction peak-based criterion (SAEPC) is established to monitor the precise instant of ...
Muhammad Saad, Chul-Hwan Kim
doaj +1 more source