Results 11 to 20 of about 176 (162)
Reliable detection of free‐air electric arc faults in high‐voltage overhead transmission lines, together with accurate discrimination between transient and permanent faults, is essential for secure single‐phase auto‐reclosing and for maintaining system ...
Mahyar Abasi +2 more
doaj +2 more sources
A Comprehensive Review of Auto-Reclosing Schemes in AC, DC, and Hybrid (AC/DC) Transmission Lines
The integration of distributed generators has changed the paradigm of modern power transmission systems. To cope with energy demands, electrical networks emphasize the efficient utilization of power transmission.
Arif Mehdi +4 more
doaj +1 more source
Adaptive sequential reclosing strategy for hybrid HVDC circuit breakers in MMC‐based DC grids
DC circuit breaker (DCCB) is one of the most promising solutions for handling DC fault in half‐bridge modular multilevel converter (MMC)‐based DC grid.
Jingqiu Yu, Zheren Zhang, Zheng Xu
doaj +1 more source
Adaptive Single-Pole Auto-Reclosing Scheme Based on Secondary Arc Voltage Harmonic Signatures
This paper presents an advanced adaptive single-pole auto-reclosing (ASPAR) scheme based on harmonic characteristics of the secondary arc voltage. For analysis of the harmonics, short-time Fourier transform (STFT), which is a universal signal processing ...
Joon Han, Chul-Moon Lee, Chul-Hwan Kim
doaj +1 more source
Uninterrupted power supply to BESS based microgrid system using adaptive reclosing approach
As more than 80% of faults on overhead lines are temporary (transient) in nature which is caused due to lightning strikes, momentary bird or tree limb contact, wind bringing conductors in contact, etc.
Shubham Ghore +2 more
doaj +1 more source
Modular multilevel converter based on high voltage director current is important for large‐scale power regional interconnection. Adaptive reclosing is critical to improving the safety and economy of power transmission.
Jingru Zhang +4 more
doaj +1 more source
An economical hybrid DC circuit breaker with pre-current-limiting capability
Multi-terminal flexible high-voltage-direct-current (HVDC) transmission and DC grid technology are developing rapidly, and the hybrid DC circuit breaker (DCCB) is usually used to protect the DC system, which can quickly remove the fault current and make ...
Guanlong Jia +4 more
doaj +1 more source
An Adaptive Reclosing Switch Based on Shunt Resistance
Abstract In order to solve problems that the low coincidence success rate of the automatic reclosure of distribution network and short-circuit current has a large impact on the system when it coincides with the permanent fault, a shunt resistance type of adaptive reclosing switch is proposed.
Jian Liu, Yu Lei, Zhihua Zhang
openaire +1 more source
Adaptive Overhead Transmission Lines Auto-Reclosing Based on Hilbert–Huang Transform [PDF]
This paper presents a reliable and fast index to detect the instant of arc extinction for adaptive single-pole automatic reclosing (ASPAR). The proposed method is a simple technique for ASPAR on shunt compensated transmission lines using the Hilbert–Huang Transform (HHT). The HHT method is a combination of the empirical mode decomposition (EMD) and the
Arman Ghaderi Baayeh, Navid Bayati
openaire +2 more sources
Energy and Load Curtailment Based Indices in Probabilistic Transient Stability Studies
In this paper, stochastic models for both simultaneous and adaptive reclosing are presented and examined using a new set of probabilistic transient stability risk indices. The developed indices are based on load curtailments resulting from bus isolations
Roy Billinton, Saleh Aboreshaid
doaj +1 more source