Results 1 to 10 of about 2,565 (167)
The doubly-fed induction generator has significant features compared to the fixed speed wind turbine, which has popularised its application in power systems.
Seyed Behzad Naderi +4 more
doaj +3 more sources
The DC fault has become one of the most serious obstacles for the development of DC system because of its wide impact range and large fault current.
Shiyuan FAN +5 more
doaj +1 more source
Fault ride-through control strategy of H-bridge cascaded energy storage system [PDF]
The cascaded energy storage system has received extensive attention in areas such as new energy consumption, maintaining stable operation of the power grid, and supporting black start due to its advantages such as high access voltage level, large single ...
Yin Shi +4 more
doaj +1 more source
Fault equivalent model for non-blocking DC fault ride-through of hybrid MMC
Compared with full-bridge modular multilevel converter (MMC), the hybrid MMC composed of half bridge sub-module and full bridge sub-module has the low cost and high DC fault ride-through capability.
WANG Zeqing +5 more
doaj +1 more source
The hybrid HVDC system based on line commutated converter and modular multilevel converter is a feasible method to address the common commutation failure at the receiving end of conventional HVDC systems. At present, project Gezhouba–Shanghai in China is
Liangliang Hao +4 more
doaj +1 more source
With the continuous improvement of the penetration level of wind power in the power system, the grid-forming mode of wind turbine will gradually become one of the main modes of system synchronization.
Jianzu Hu +4 more
doaj +1 more source
Fault Ride-Through Strategy for GFM Inverters Based on Power Command Constraints [PDF]
[Objective] To address the issues of power angle instability and output current overload in grid-forming(GFM)inverter during symmetrical grid faults,this paper proposes a fault ride-through strategy based on power command constraints.
LIU Yiqi, ZHAO Bo, LAN Hao, ZHANG Hengke, WANG Zeyang, WU Yucheng
doaj +1 more source
Aiming at the problems of DC fault isolation and power surplus in the HVDC system with large-scale wind farm (WF) integration after single-pole grounding fault, this article designs a modified current transfer modular multilevel converter (M-CT-MMC ...
Bo Zhu +5 more
doaj +1 more source
Mechanical Switch Based Adaptive Fault Ride-through Strategy for Power Quality Improvement Device
Cascaded H-bridge power quality improving device (PQID) has garnered extensive attention for its flexible electric energy conversion and fast voltage response.
Yu Shen +6 more
doaj +1 more source
An Analytical Short-Circuit Current Calculation Method for Full-Power Wind Turbines under Complete Fault Ride-Through Processes [PDF]
Accurate calculation of short-circuit current throughout the fault ride-through process of wind turbines is a critical prerequisite for the analysis and control of modern power systems.
YUAN Shuai, XIAO Jiaan, TAO Jun, CUI Haohan, CHAO Pupu, LI Weixing, A Minfu, WANG Liqiang, ZHONG Ming
doaj +1 more source