Results 31 to 40 of about 2,556 (266)
Converter-interfaced renewable energy sources (CIRESs) may have a different fault current angle with synchronous generators (SGs), so the large angle difference on both sides will cause low sensitivity or failure for traditional proportional braking ...
Zhe Yang +3 more
doaj +1 more source
Impact of Grid Unbalances on Electric Vehicle Chargers
There is a global trend to reduce emissions from cars through the adoption of other alternatives, such as electric vehicles (EVs). The increasing popularity of EVs has led to a growing demand for electric vehicle chargers.
Sultan Alwahaibi +3 more
doaj +1 more source
Decentralised control and fault ride‐through of a multi‐microgrid system [PDF]
A multi‐microgrid (MMG) system comprises of a cluster of microgrids interconnected for reliable and efficient operation in grid connected as well as islanded modes. In this study, the fault‐ride‐through capability of an MMG system is addressed. A solution to under‐voltage and over‐current scenarios arising due to severe short‐circuit faults in inverter‐
Saroja Kanti Sahoo +3 more
openaire +2 more sources
This article presents an experimental and numerical modal investigation of composite sandwich structures using surfboards as model systems. By comparing different core materials and reinforcement strategies, the study demonstrates how local stiffeners influence vibrational response and introduce characteristic modal features, highlighting modal ...
Brett Connellan +4 more
wiley +1 more source
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
Fluorescent BODIPY‐conjugated thiosemicarbazone ligands and their Ga(III), In(III), and Fe(III) complexes, inspired by Triapine, are developed as theranostic agents. Multiphoton FLIM and confocal microscopy in cancer cells and zebrafish reveal real‐time uptake, mitochondrial localisation, and whilst spectroscopic assays indicated preserved complex ...
Megan J. Green +15 more
wiley +1 more source
This article provides insights into the dynamic performance of indirect and direct control strategies for grid-forming (GFM) inverters. The indirect method for grid-forming inverters utilizes three cascaded stages to produce the reference signal sent to ...
Mehmetcan Gursoy, Behrooz Mirafzal
doaj +1 more source
Analysis of fault ride through in wind farms during network faults
Fault Ride Through (FRT) is a term used to describe the ability of wind farms to remain connected to the system during disturbances, such as short circuits or voltage drops. This capability is vital for maintaining the stability of power systems and preventing the adverse consequences that may arise from wind power outages during disturbances.
Rajić, Tomislav +3 more
openaire +2 more sources
Abstract Large‐scale land reforms constitute a substantial redistribution of wealth and reallocation of agricultural land, which is a major form of asset and production input in developing countries. While land redistribution (from the rich to the poor) remains a highly controversial issue, extensive evidence on its effect is limited.
Devashish Mitra +3 more
wiley +1 more source
A grid side fault ride-through control for renewable energy connected MMC-HVDC
Renewable energy connected modular multilevel converter high-voltage direct-current (MMC-HVDC) system should have the capability of fault ride-through when the AC grid fails. However, it is difficult to quickly and reliably achieve fault ride-through via
Qiang HUANG +5 more
doaj +1 more source

