Results 31 to 40 of about 2,565 (167)
Fault Ride Through approach for Grid-Connected Photovoltaic System
This paper presents a fault ride-through approach for grid-connected photovoltaic (PV) systems, aimed at improving the system's response during voltage sags and limiting the maximum inverter current during symmetrical faults.
Komal Bai +2 more
doaj +1 more source
Converter-interfaced renewable energy sources (CIRESs) may have a different fault current angle with synchronous generators (SGs), so the large angle difference on both sides will cause low sensitivity or failure for traditional proportional braking ...
Zhe Yang +3 more
doaj +1 more source
A grid side fault ride-through control for renewable energy connected MMC-HVDC
Renewable energy connected modular multilevel converter high-voltage direct-current (MMC-HVDC) system should have the capability of fault ride-through when the AC grid fails. However, it is difficult to quickly and reliably achieve fault ride-through via
Qiang HUANG +5 more
doaj +1 more source
Hierarchical control-based fault ride-through of VSC-HVDC considering impacts of renewable energy
When a short-circuit fault occurs at the receiving-end grid, the unbalanced power in voltage source converter based high voltage direct current (VSC-HVDC) should be consumed to prevent excessive DC voltage rise, thereby enabling fault ride-through ...
Jinxin Ouyang, Fan Mo, Jiyu Chen
doaj +1 more source
This article provides insights into the dynamic performance of indirect and direct control strategies for grid-forming (GFM) inverters. The indirect method for grid-forming inverters utilizes three cascaded stages to produce the reference signal sent to ...
Mehmetcan Gursoy, Behrooz Mirafzal
doaj +1 more source
Decentralised control and fault ride‐through of a multi‐microgrid system [PDF]
A multi‐microgrid (MMG) system comprises of a cluster of microgrids interconnected for reliable and efficient operation in grid connected as well as islanded modes. In this study, the fault‐ride‐through capability of an MMG system is addressed. A solution to under‐voltage and over‐current scenarios arising due to severe short‐circuit faults in inverter‐
Saroja Kanti Sahoo +3 more
openaire +2 more sources
Analysis of fault ride through in wind farms during network faults
Fault Ride Through (FRT) is a term used to describe the ability of wind farms to remain connected to the system during disturbances, such as short circuits or voltage drops. This capability is vital for maintaining the stability of power systems and preventing the adverse consequences that may arise from wind power outages during disturbances.
Rajić, Tomislav +3 more
openaire +2 more sources
Fault Ride-Through Study of Wind Turbines
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT). To study the FRT operation of the wind farms, three methods were discussed.
Xinyan Zhang +3 more
openaire +2 more sources
Doubly fed induction generator (DFIG) is the most popular machine for the wind power application that consists of the ability for variable speed operation and reactive power control with the help of power electronics converters.
Prashant Mani Tripathi +2 more
doaj +1 more source
As the penetration rate of wind turbines gradually increases, the fluctuation of system voltage and frequency significantly increases under power grid fault.
Zhongliang Li, Fang Liu
doaj +1 more source