Results 51 to 60 of about 2,565 (167)
Due to the complexity of wind farm environments and the particularity of DC systems, fault signals may be affected by numerous factors, which can compromise the accuracy of fault detection.
Lei Chen, Qi Han
doaj +1 more source
To address the difficulty in accurately characterizing the fault current response of renewable energy grid-connected devices during high-/low-voltage ride-through, this paper proposes a fault current response modeling and parameter identification method ...
Jiayang Zhou +5 more
doaj +1 more source
Evaluating a Hybrid Circuit Topology for Fault-Ride through in DFIG-Based Wind Turbines. [PDF]
Saeed S +5 more
europepmc +1 more source
Control Strategy of Low-voltage Ride-through for Micro-grid under Asymmetric Grid Voltage
It researched the control strategy of micro-grid low voltage ride-through under asymmetric grid voltage, established a mathematical model of micro- grid stability controller under asymmetric grid voltage for low voltage ride- through of micro-grid under ...
XU Liang, HAN Minxiao
doaj
At present, the equivalent modeling method of wind farms mostly adopts single-machine multiplication equivalence, which has the deficiencies of large model error and difficulty in accurately reflecting the fault transient characteristics of wind farms ...
Jianan He +8 more
doaj +1 more source
Coordinate Fault Ride-Through Strategy for Connection of Offshore Wind Farms Using Voltage Source-Converter-Based High-Voltage Direct-Current Transmission under Single Polar Fault. [PDF]
Zhou H, Ge S, Qin L.
europepmc +1 more source
Renewable energy sources (RES) are being integrated to electrical grid to complement the conventional sources to meet up with global electrical energy demand.
M. Shuaibu, A. S. Abubakar, A. F. Shehu
doaj
Fault Ride Through Control of Multiport Converter for Distribution Grids
Domínguez-Hernàndez, Martí +4 more
openaire +3 more sources
Due to the wide application of modular multilevel converters (MMCs) in hybrid AC/DC distribution grids, enhancing the fault ride-through (FRT) capability of MMC is essential to improve the reliability of the hybrid AC/DC distribution grids. In this paper,
Yu Chen +3 more
doaj +1 more source
Based on the complementary advantages of Line Commutated Converter (LCC) and Modular Multilevel Converter (MMC) in power grid applications, there are two types of hybrid DC system topologies: one is the parallel connection of LCC converter stations and ...
Xinshou Tian +3 more
doaj +1 more source