Results 91 to 100 of about 11,960 (229)
Due to the wide application of modular multilevel converters (MMCs) in hybrid AC/DC distribution grids, enhancing the fault ride-through (FRT) capability of MMC is essential to improve the reliability of the hybrid AC/DC distribution grids. In this paper,
Yu Chen +3 more
doaj +1 more source
Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability.
Md. Rashidul Islam +5 more
doaj +1 more source
Comparative Impedance Characteristic Analysis of Grid‐Following and Grid‐Forming Inverters
This paper comprehensively analyses the impedance characteristics of grid‐following and grid‐forming inverters at around synchronous frequency areas considering various operating and grid connection conditions and control settings. Both analytical and from EMT‐simulation extracted impedances are obtained for ensuring model plausibility.
Yonggang Zhang +3 more
wiley +1 more source
Capacitor Voltage Imbalance Mechanism and Balancing Control of MMC When Riding Through PTG Fault
Modular multilevel converter (MMC) based fault ride through (FRT) control is a promising solution to deal with the pole-to-ground (PTG) fault in high voltage direct current (HVDC) system.
Zhen He +4 more
doaj +1 more source
Power Quality Improvement and Low Voltage Ride through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer [PDF]
© 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission.This paper proposes the application of a dynamic voltage restorer (DVR) to ...
Allaoui, Tayeb +3 more
core +2 more sources
A Fuzzy Logic Controller to Increase Fault Ride-Through Capability of Variable Speed Wind Turbines
A fuzzy controller for improving Fault Ride-Through (FRT) capability of Variable Speed Wind Turbines (WTs) equipped with Doubly Fed Induction Generator (DFIG) is presented.
Geev Mokryani +3 more
doaj +1 more source
Wind power has developed rapidly in recent years, and large-scale wind power facilities connected to power grids will bring many new challenges. Some new operation characteristics of power grids with doubly-fed induction generator (DFIG) may exhibit, for
Xinshou Tian +5 more
doaj +1 more source
Comparative Evaluation between Direct Connected and VSC-HVDC Grid Connected Wind Farm [PDF]
Nowadays, the penetration level of wind power generation plants has reached a high level. The double Fed Induction Generator (DFIG) based wind turbines are the most preferred type, due to their advantages.
E. Kahn, Mohamed Tariq +1 more
core +1 more source
This paper proposes an ac fault ride-through (FRT) method for high-voltage dc (HVDC) transmission systems that serve as an interconnector between the onshore ac grid and an islanded offshore ac grid.
Nikola Krneta, Kenichiro Sano
doaj +1 more source
Fault Ride-Through Capacity Enhancement of Fixed Speed Wind Generator by A Modified Bridge-type Fault Current Limiter [PDF]
Fault Ride-Through (FRT) is a common requirement to abide by grid code all over the world. In this work, to enhance the fault ride-through capability of a fixed speed wind generator system, a modified configuration of Bridge-Type Fault Current Limiter ...
Rashid, Gilmanur