Results 91 to 100 of about 15,910,061 (175)
This paper analyzes and proposes a novel scheme with suitable control strategy to increase the probability of successful fault ride-through (FRT) as well as to enhance the rotor speed stability of doubly fed induction generator (DFIG) based wind farms ...
M P Selvan, K Vinothkumar
core +1 more source
This paper proposes an ac fault ride-through (FRT) method for high-voltage dc (HVDC) transmission systems that serve as an interconnector between the onshore ac grid and an islanded offshore ac grid.
Nikola Krneta, Kenichiro Sano
doaj +1 more source
Fault Ride-Through Study of Wind Turbines
The installation of wind energy has increased rapidly around the world. The grid codes about the wind energy require wind turbine (WT) has the ability of fault (or low voltage) ride-through (FRT).
Xinyan Zhang +3 more
core
Large-scale centralized photovoltaic power plants (PVPPs) connected to a power grid may cause short-term voltage instabilities during fault ride-through (FRT) processes.
Boyang Li +5 more
doaj +1 more source
Increasing integration of renewable energy resources emphasizes the importance of the grid-forming virtual synchronous generator (VSG)-based converters.
Khan, Basit +4 more
core +1 more source
Fault Current Suppression for the Fault Ride-Through of Triple-Active-Bridge Converters
The fault ride-through (FRT) capability is an important ancillary service for power converters in dc power distribution systems. Despite extensive research, the triple active bridge converter (TABC) has been perceived as lacking FRT capability due to the
Wang, Yanbo +4 more
core +1 more source
Fault Ride-Through Characteristics of Small Wind Turbines
There is significant potential for an increase in the use of kilowatt-class small wind turbines (SWTs) in Japan due to reduced limitations with respect to installation, despite their high cost.
Junji Kondoh +2 more
core +1 more source
In the inverter-based resource (IBR) transmission system, the fault ride-through (FRT) control of the IBR significantly modifies its fault characteristics.
Hongyue Ma +4 more
doaj +1 more source
Grid fault ride-through capability of voltage-controlled inverters for distributed generation applications. [PDF]
The increased integration of distributed and renewable energy resources (DERs) has motivated the evolution of new standards in grid interconnection requirements.
Piya, Prasanna
core
Coordinate Fault Ride-Through Strategy for Connection of Offshore Wind Farms Using Voltage Source-Converter-Based High-Voltage Direct-Current Transmission under Single Polar Fault. [PDF]
Zhou H, Ge S, Qin L.
europepmc +1 more source