Results 171 to 180 of about 11,960 (229)

Fault-Ride-Through (FRT) Characteristics of a Power-Decoupling-Type Photoinverter System

open access: closed2019 IEEE Applied Power Electronics Conference and Exposition (APEC), 2019
The fault-ride-through (FRT) performance of a power conditioner equipped with a power decoupling function and the design requirements for power decoupling that can ensure stable operation are evaluated in this paper. To realize a power conditioner with a long lifetime and high power density, many types of power decoupling functions have been proposed ...
Taiki Onodera, Toshihisa Shimizu
semanticscholar   +3 more sources

A New Fault Ride-Through (FRT) Topology for Induction Generator Based Wind Energy Conversion Systems

open access: closedIEEE Transactions on Power Delivery, 2019
Leading wind turbine manufacturers are running life extension programs for their installed wind farms which include fixed speed induction generator-based wind turbines (FSIG-WT). To accommodate the requirement of recent grid codes in these upgrades, this paper presents a new topological configuration to enhance the fault ride through (FRT) operation of
Abdul Mannan Rauf   +2 more
semanticscholar   +3 more sources

Hardware Validation of Virtual Impedance-Based Fault-Ride-Through (FRT) Control for Grid-Forming (GFM) Inverter

open access: closed2025 IEEE Power & Energy Society General Meeting (PESGM)
This paper presents the hardware validation of a virtual impedance-based fault ride-through (FRT) control strategy for grid-forming (GFM) inverter, ensuring reliable operation under fault condition.
Shuvangkar Chandra Das   +9 more
semanticscholar   +3 more sources

Integration of Solar Energy into Electric Vehicle Charging Stations with Fault Ride Through (FRT) Capability Under Critical Voltage Conditions

open access: closed2025 IEEE 3rd International Symposium on Sustainable Energy, Signal Processing and Cybersecurity
Maintaining grid resilience and power quality is made more difficult by the explosive expansion of EV charging infrastructure, particularly during voltage disruptions.
Lagudu Suri Demudu   +5 more
openalex   +2 more sources

Enhancing microgrid resilience through integrated grid-forming and grid-following inverter strategies for solar PV battery control and fault ride-through [PDF]

open access: yesSci Rep
This study investigates the integration of a Grid-Forming (GFM) Battery Energy Storage System (BESS) to enhance the stability of microgrids in the presence of high renewable energy penetration. The proposed GFM inverter, combined with BESS, significantly
Md. Ismail Hossain   +6 more
semanticscholar   +2 more sources

Improved Fault Ride-Through Response of Grid Forming Inverters Under Symmetrical and Asymmetrical Faults

IEEE transactions on energy conversion
The voltage source behaviour of grid forming inverters is in demand owing to their instantaneous reaction to disturbances in the grid. However, this might lead to the flow of high magnitudes currents during faults.
Imran Khan, S. Doolla
semanticscholar   +1 more source

Grid-Forming Control of DFIG-Based Wind Turbine Generator by Using Internal Voltage Vectors for Asymmetrical Fault Ride-Through

IEEE transactions on energy conversion
Grid-forming (GFM) controls exhibit robust frequency and voltage support capabilities for inverter-based resources (IBRs). This also shows promise for doubly fed induction generator-based wind turbine generators (DFIG-based WTGs).
Xinquan Chen, Yuanzhu Chang, I. Kocar
semanticscholar   +1 more source

Enhancing Fault Ride-Through Capability of DFIG-Based WECS Using Dynamic Reconfiguration Hybrid Interlinking Transformer Technique

IEEE Transactions on Sustainable Energy
The abnormal grid voltages, such as sags, swells, and harmonics caused by grid faults, seriously threaten the safe operation of a doubly-fed induction generator (DFIG)-based wind energy conversion system (WECS).
J. Lai   +7 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy