Results 51 to 60 of about 5,122 (298)
Fault ride-through of doubly-fed induction generator with converter protection schemes [PDF]
This paper from the point view of wind farm fault ride-through (FRT) capability, discusses the performance of converter protection schemes to it. Different resistor protection methods are summarized and then a new combined protection with crowbar (CB ...
John E. Fletcher +5 more
core +1 more source
Abstract Discrete choice experiments are increasingly being used to estimate land managers' willingness to accept participation in incentive‐based environmental programs. This is a specific application of discrete choice experiments: the estimation of willingness to accept for a private good (program participation) where respondents have to make trade ...
Anastasio J. Villanueva +2 more
wiley +1 more source
ABSTRACT Autosomal recessive HARS1‐related disorder (originally described as Usher syndrome type 3B) caused by a homozygous Y454S variant in the histidyl‐tRNA synthetase gene (HARS1) is characterized by progressive sensorineural hearing and vision loss and respiratory deterioration with risk for sudden death following febrile illnesses.
Victoria Mok Siu +23 more
wiley +1 more source
Graphical abstract summarizing the study design, main results and key findings Abstract Background and Aims Fatty liver disease (FLD) has been associated with excess mortality. Screening for hepatic steatosis (HS) in patients with metabolic dysfunction is therefore recommended by several guidelines, despite a paucity of evidence on the clinical ...
Laurens A. van Kleef +5 more
wiley +1 more source
Doubly fed induction generator (DFIG) is the most popular machine for the wind power application that consists of the ability for variable speed operation and reactive power control with the help of power electronics converters.
Prashant Mani Tripathi +2 more
doaj +1 more source
As the penetration rate of wind turbines gradually increases, the fluctuation of system voltage and frequency significantly increases under power grid fault.
Zhongliang Li, Fang Liu
doaj +1 more source
Abstract A recent debate has emerged between Caspar et al. (2024) and Herculano‐Houzel (2023) on inferring extinct dinosaur cognition by estimating brain neuron counts. While thought‐provoking, the discussion largely overlooks the function of cognition, as well as partly neglects the difficulties involved in estimating neuron numbers, which according ...
Thomas Rejsenhus Jensen +7 more
wiley +1 more source
Wind farms integrated to an AC power system through a voltage source converter-based high-voltage direct current system (VSC-HVDC) are viewed as islanded wind farms. The wind farm side converter of VSC-HVDC maintains a constant frequency of the wind farm
Yan Li +3 more
doaj +1 more source
The photovoltaic power station has a good development prospect because it can realize concentrated and efficient utilization of solar energy. Considering the detail model of the photovoltaic power station has a power electronic device with a high ...
Xian Xu +5 more
doaj +1 more source
Fault Ride-Through Characteristics of Small Wind Turbines [PDF]
There is significant potential for an increase in the use of kilowatt-class small wind turbines (SWTs) in Japan due to reduced limitations with respect to installation, despite their high cost. At this stage, the Japanese grid code has not been considered sufficiently with respect to grid-connected SWTs, and the addition of fault ride-through (FRT ...
Junji Kondoh +2 more
openaire +1 more source

