Results 31 to 40 of about 5,304 (193)
O mercado global de energia elétrica está crescendo a uma taxa de cerca de 100 GW por ano e até recentemente, essa demanda era atendida por meio de plantas de geração centralizadas. No entanto, essa estrutura centralizada é ineficiente e poluente.
openaire +1 more source
Illustration of Modern Wind Turbine Ancillary Services [PDF]
Increasing levels of wind power penetration in modern power systems has set intensively high standards with respect to wind turbine technology during the last years.
Anca D. Hansen +5 more
core +2 more sources
Power systems protection has become more vital in recent years to ensure stability, reliability, security, and power quality due to the exponential growth of grid-connected photovoltaic (GCPV) systems. As a result, several nations have set new grid codes
Izhar Ahmad Saifi +3 more
doaj +1 more source
Comprehensive fault ride-through scheme for doubly-fed induction generators
With the growth of wind energy penetration in electricity transmission grids, fault ride-through (FRT) ability is required in order to maintain the uninterrupted operation of wind farm in voltage disturbance scenarios.
Fan Cheng +4 more
doaj +1 more source
Techniques for Ensuring Fault Ride-Through Capability of Grid Connected DFIG-Based Wind Turbine Systems: A Review [PDF]
Renewable energy sources (RES) are being integrated to electrical grid to complement the conventional sources to meet up with global electrical energy demand.
Abubakar, A.S., Shehu, A.F., Shuaibu, M.
core +2 more sources
For future multi‐terminal HVDC networks, protection systems based on DC circuit breakers (DCCBs) are envisioned to limit the loss of power transmission towards AC grid(s). Yet, HVDC protection system design is considered a major challenge—especially in a
Patrick Düllmann +3 more
doaj +1 more source
High penetration of Doubly Fed Induction Generator (DFIG) into existing power grid can attribute complex issues as they are very sensitive to the grid faults.
Md. Rashidul Islam +6 more
doaj +1 more source
Enhanced DC voltage control strategy for fault management of a VSC-HVDC connected offshore wind farm [PDF]
This paper proposes a DC voltage control strategy for fault management taking into advantage the operation of the master controller located in the offshore AC substation platform.
Booth, Campbell +3 more
core +1 more source
Nonlinear Power Transfer Matrix Model for Power Control and Modeling of PMSG‐Wind Turbines ABSTRACT This paper presents the Lyapunov stability scheme based nonlinear power transfer matrix (NLPTM) model for controlling and modeling the permanent magnet synchronous generator (PMSG) based wind turbine.
Muhammad Ali Bijarani +5 more
wiley +1 more source
Wind farms equipped by Doubly-Fed Induction Generators (DFIG) should have two capabilities so that system operators can efficiently utilizes them. These capabilities include Fault-Ride-Through (FRT) and smoothing the output active power fluctuations ...
Mostafa Sedighizadeh +2 more
doaj +1 more source