Results 51 to 60 of about 5,304 (193)

Optimal Linear Protection Scheme of Inverter‐Based Distributed Energy Resources: Meeting Fault‐Ride‐Through Requirement

open access: yesInternational Journal of Energy Research, Volume 2026, Issue 1, 2026.
This paper presents a new two‐stage protection strategy for active distribution networks that not only addresses selectivity constraints along protected lines but also incorporates fault‐ride‐through (FRT) requirements of inverter‐based distributed energy resources (IBDERs). The proposed coordination strategy (PCS), which distinguishes it from previous
Amin Yazdaninejadi   +4 more
wiley   +1 more source

Enhanced fault ride-through control for grid-forming inverters: comparative analysis and adaptive strategies

open access: yesInternational Journal of Electrical Power & Energy Systems
As renewable energy technologies increasingly dominate as primary power sources, grid-forming (GFM) inverters have emerged as crucial components for future low inertia power systems, offering flexible inertia support and autonomous grid-forming ...
Liang Yuan   +5 more
doaj   +1 more source

Establishing the Partial Load Limits for Main Shaft Response Prediction in Wind Turbine Hybrid Nacelle Testing

open access: yesWind Energy, Volume 28, Issue 5, May 2025.
ABSTRACT Hybrid nacelle testing is a novel testing method that utilizes partial load tests in combination with virtual models to extrapolate the response at full load of the nacelle device under test. Validation of the virtual model at partial loads plays a crucial role in this type of hybrid test approach.
Muhammad Omer Siddiqui   +2 more
wiley   +1 more source

A novel FRT strategy for transformerless MMC to improve current differential protection performance under single-phase grounding faults

open access: yesInternational Journal of Electrical Power & Energy Systems
AC/DC distribution networks are interconnected by converters such as modular multilevel converters (MMCs). In AC/DC distribution networks, single-phase grounding (SPG) faults can cause enormous challenges in relay protection.
Yuze Li   +3 more
doaj   +1 more source

Fault Ride-Through Operation Analysis of Doubly Fed Induction Generator-Based Wind Energy Conversion Systems: A Comparative Review

open access: yesEnergies, 2022
In present electrical power systems, wind energy conversion systems based on doubly fed induction generators represent one of the most commonly accepted systems in the global market due to their excellent performance under different power system ...
Aftab Ahmed Ansari, Giribabu Dyanamina
doaj   +1 more source

International White Book on DER Protection : Review and Testing Procedures [PDF]

open access: yes, 2011
This white book provides an insight into the issues surrounding the impact of increasing levels of DER on the generator and network protection and the resulting necessary improvements in protection testing practices.
Abdulhadi, Ibrahim Faiek   +7 more
core  

Blocking Converter Criteria Considering Protection Coordination Strategies of VSC‐MTDC

open access: yesIET Energy Systems Integration, Volume 7, Issue 1, January/December 2025.
ABSTRACT Multiterminal high‐voltage direct current (MTDC) systems are anticipated to enable the massive integration of renewable energies into modern grids. However, the protection of MTDC systems is a major challenge for their application in connection with offshore wind farms (OWF).
Jalal Sahebkar Farkhani   +4 more
wiley   +1 more source

Receiving-end AC fault ride-through method of hybrid HVDC transmission based on adaptive DC voltage reduction

open access: yesInternational Journal of Electrical Power & Energy Systems
The hybrid high-voltage direct current (HVdc) transmission that combines line-commutated converters (LCCs) at the sending end and modular multilevel converters (MMCs) at the receiving end is a promising choice for integrating bulk renewable power ...
Kailun Wang, Qiang Song, Qianhao Sun
doaj   +1 more source

Harmonic suppression and fault ride‐through method of diode‐rectifier‐based hybrid high‐voltage direct current system for offshore wind farms integration

open access: yesIET Generation, Transmission & Distribution, 2023
The diode‐rectifier (DR)‐based high‐voltage direct current (HVDC) transmission is regarded as a low‐cost alternative to the HVDC transmission for offshore wind farms (OWFs) integration.
Zixi Fang   +5 more
doaj   +1 more source

Coordination between Fault-Ride-Through Capability and Overcurrent Protection of DFIG Generatorsfor Wind Farms [PDF]

open access: yes, 2009
Due to the increasing penetration of wind farms in power systems, stability issues arise strongly for power system operation. Doubly-Fed Induction Generators (DFIG) are charac-terized with some unique features during normal/abnormal op-erating conditions
Abdel-Rahman, Mansour H.   +2 more
core   +1 more source