Results 81 to 90 of about 5,325 (194)
This paper presents the control design of a new modular integrated on‐board charger (MIOBC) for EVs. The proposed MIOBC modularises both the battery and power converters, enhancing controllability and fault‐ride‐through (FRT) capability. Integrating the traction inverter with the OBC reduces system size and weight while enabling seamless operation in ...
Fatemeh Nasr Esfahani +2 more
wiley +1 more source
An Enhanced Fault Ride‐Through Control Method of the VSG Based on Dynamic Power Compensation
To enhance the fault ride‐through (FRT) capability for the VSGs, an FRT control method based on dynamic power compensation (DPC) is proposed in this article, which comprehensively considers both the fault current limitation and power angle stability for the VSG.
Xueqing Li +5 more
wiley +1 more source
Study on the fault ride through critical elements and coordinated control of DFIG's converters
The increasing of large-scale wind power integration capacity brings great challenges to the safe operation and management of power grid.
Bingjie Tang +4 more
doaj +1 more source
Optimized design of power loops for virtual synchronous generator to enhance transient stability
Abstract Virtual synchronous generator (VSG) control is an attractive method to solve the stability issues of future renewables (e.g. photovoltaic [PV])‐dominated power system. Unfortunately, a VSG is prone to transient instability under grid faults, and the existing work ignores the instability issues caused by current limitation and reactive power ...
Xudong Zou +5 more
wiley +1 more source
The growing level of grid-connected renewable energy sources in the form of microgrids has made it highly imperative for grid-connected microgrids to contribute to the overall system stability.
Elutunji Buraimoh +2 more
doaj +1 more source
Arbitrarily fast delayed signal cancellation PLL for grid‐integration of renewable energy sources
Figure 1 shows the block diagram of renewable energy sources powered grid‐connected converter. This figure highlights the importance of grid‐synchronization in integrating renewable energy sources into the grid. Abstract Integrating renewable energy sources into an unbalanced distribution network requires fast and accurate extraction of fundamental ...
Hafiz Ahmed +2 more
wiley +1 more source
Due to the wide application of modular multilevel converters (MMCs) in hybrid AC/DC distribution grids, enhancing the fault ride-through (FRT) capability of MMC is essential to improve the reliability of the hybrid AC/DC distribution grids. In this paper,
Yu Chen +3 more
doaj +1 more source
Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability.
Md. Rashidul Islam +5 more
doaj +1 more source
This article presents a solar energy microgrid designed to address DC‐link voltage instability in both grid‐connected and standalone modes. A reserve energy management scheme utilizing batteries and supercapacitors is developed to regulate DC‐link voltage, minimizing stress on capacitors and enhancing system reliability.
Saqif Imtiaz +5 more
wiley +1 more source
Coordination between Fault-Ride-Through Capability and Overcurrent Protection of DFIG Generatorsfor Wind Farms [PDF]
Due to the increasing penetration of wind farms in power systems, stability issues arise strongly for power system operation. Doubly-Fed Induction Generators (DFIG) are charac-terized with some unique features during normal/abnormal op-erating conditions
Abdel-Rahman, Mansour H. +2 more
core +1 more source