Performance Prediction of a Single-Zone Vertical Feedwater Heater
ASME 2010 Power Conference, 2010This paper represents a case study of a replacement single-zone vertical feedwater heater with a pump forward drains system. When replacing a feedwater heater, it is important to review, evaluate and adjust the NLL of the new heater since it may not be the same as the NLL of the existing heater in order to achieve the same performance, particularly ...
Eric Svensson, William Mirowski
openaire +1 more source
Dynamic Simulation on Feedwater Heater of Nuclear Power Plant
Advanced Materials Research, 2012There is not only the flow of the single-phase fluid but also the mixed-flow of the gas-liquid fluid in the system. So, it is very necessary to study its operational characteristics. In this study, the low pressure heaters (LP heaters) in the feedwater system are simulated.
Chun Guo Wang, Rui Yu, Ke Long Zhang
openaire +1 more source
Selecting Shell Side Design Temperature for Feedwater Heaters
Volume 1: Fuels and Combustion, Material Handling, Emissions; Steam Generators; Heat Exchangers and Cooling Systems; Turbines, Generators and Auxiliaries; Plant Operations and Maintenance; Reliability, Availability and Maintainability (RAM); Plant Systems, Structures, Components and Materials Issues, 2014Operating temperature information was gathered using thermocouples installed on the outside of an existing high pressure feedwater heater (FWH). The operating data was collected to demonstrate the basis for the evaluation of the operational effectiveness of the heater especially during rapid load changes.
openaire +1 more source
The impact of fouling on performance evaluation of multi-zone feedwater heaters
Applied Thermal Engineering, 2007A numerical method for analyzing closed system feedwater heaters is presented. A general approach to determine area allocations among the desuperheating, condensing and subcooling zones under a known set of operating conditions is presented for a feedwater heater in a steam power plant.
Mohamed A. Antar, Syed M. Zubair
openaire +1 more source
Level control in feedwater heater systems using nonlinear strategies
ISA Transactions, 1998Abstract This paper deals with the level control of a horizontal closed feedwater heater in a power generation plant. Due to inherent nonlinearities in the system, conventional PI controllers are often tuned conservatively to preserve stability and hence result in suboptimal performance.
C. Thanomsat, C.W. Taft, A.M. Annaswamy
openaire +1 more source
Performance and Service Life Considerations—Closed Feedwater Heaters
Heat Transfer Engineering, 1987Because of the potential restriction of plant capacity and increases in fuel consumption cost that result from the removal of closed feedwater heaters from service, there is a need for the application of new design and operation concepts that enhance both the thermal performance and the availability of heaters and their associated systems.
openaire +1 more source
Failure of Low Pressure Feedwater Heater Tubing-A Case History
CORROSION 1986, 1986Abstract A work program consisting of failure analysis, laboratory tests and feed-water chemistry monitoring was carried out to determine the root cause of low pressure Admiralty brass feedwater heater failures and recommend ammeliorative solutions. The results of this failure analysis showed that the tubes failed due to a
A.V. Manolescu, F. Chiarotto, P. Mayer
openaire +1 more source
Prompt Leak Detection for High Pressure Feedwater Heaters
2002 International Joint Power Generation Conference, 2002I. THE NEED. A. In high pressure feedwater heaters, a tube leak quickly claims several neighboring tubes as collateral victims. B. Prompt detection of the initial leak would save the neighboring tubes from damage and preclude a potential turbine water induction incident. II. EXAMPLE. A. A Midwest generating station replaced 12 old high pressure heaters.
openaire +1 more source
Optimizing Feedwater Heater Operation in a Nuclear Power Plant
ASME 2005 Power Conference, 2005Feedwater heaters are a tough application even in a conventional power plant. Because of the complicated control scheme and the cascading effects between heaters, the levels in the heaters tend to cycle, reducing their ability to effectively transfer heat to the feedwater and wearing out many of the components that surround them. This situation is made
openaire +1 more source
Thermal modelling of feedwater heaters
2016Manufacturers of feedwater heaters (FWHs) are obliged to disclose a specification sheet to the client that describes their FWH design. However, the client is unable to verify the performance of this FWH design without comparing it to the results that are predicted by a thermal model.
openaire +1 more source