Results 51 to 60 of about 821,877 (302)

Non-traumatic Atypical Peri-implant Femoral Fracture at the Distal Screw after Short Femoral Nail Fixation for a Pertrochanteric Fracture [PDF]

open access: yes, 2020
This is the second report of an atypical peri-implant femoral fracture occurring at the distal screw after intramedullary nail fixation of a pertrochanteric fracture.
Dan’ura, Tomoyuki   +3 more
core   +1 more source

3D‐Printed Titanium Gyroid Scaffold Structure Integrated With Tough Hybrid Materials for Cartilage Replacement

open access: yesAdvanced Engineering Materials, EarlyView.
This study proposes a potential device design for joint cartilage replacement. Silica‐polytetrahydrofuran (SiO2‐PolyTHF) hybrids with customizable mechanical properties were developed to mimic the characteristics of a natural meniscus. These were synthesized through a two‐pot sol–gel hybrid process.
Yu‐Chien Lin   +12 more
wiley   +1 more source

Treatment of postoperative non-union with internal fixation loosening of Garden IV femoral neck fracture with teriparatide in a young adult: A case report

open access: yesFrontiers in Surgery, 2022
BackgroundPostoperative non-union of femoral neck fracture often needs secondary operation. We report a case of a postoperative non-union of femoral neck fracture treated with teriparatide.Case presentationA young male patient with Garden IV femoral neck
Lili Lai   +5 more
doaj   +1 more source

Proximal femoral fracture after hip resurfacing managed with blade-plate fixation. A case report [PDF]

open access: yes, 2008
Periprosthetic and proximal femoral fractures that occur after hip resurfacing are a challenging problem which, with the increasing popularity of resurfacing arthroplasty, is likely to increase in frequency.
Weinrauch, Patrick C.   +4 more
core   +1 more source

Biodegradable and Biocompatible Functional Polymers for Biomedical Applications

open access: yesAdvanced Functional Materials, EarlyView.
Biodegradable and biocompatible functional polymers integrate electrical, mechanical, and stimuli‐responsive functionalities while enabling programmed degradation under physiological conditions. This review introduces recent advances in conductive, shape‐memory, self‐healing, photocurable, and adhesive polymer systems, emphasizing material design ...
Won Bae Han   +5 more
wiley   +1 more source

Incomplete femoral neck fracture with characteristics of atypical femoral fracture: A case report and literature review

open access: yesTrauma Case Reports
Femoral neck fractures are considered exclusion criteria for atypical femoral fractures; however, femoral neck fractures with atypical femoral fractures have also been reported.
Yasuhiro Higai   +8 more
doaj   +1 more source

Bisphosphonate-related bilateral atypical femoral fractures : be aware and beware [PDF]

open access: yes, 2011
Although bisphosphonates have a well established therapeutic role in the prevention of osteoporosis-related fractures, several reports published over the past 5-6 years suggest a possible causative relationship between long-term use of bisphosphonates ...
Depasquale, Ruben   +2 more
core  

Dynamic Physicochemical Gradients for Tendon–Bone Regeneration

open access: yesAdvanced Functional Materials, EarlyView.
Dynamic physicochemical gradients offer a framework for reconnecting soft tendon and hard bone. This Review examines how hydration, transport, loading and degradation reshape these gradients during healing. Coordinating regional biological cues with progressive transfer of load from scaffold to tissue guides the design of interfaces that retain ...
Wanxue Wang   +11 more
wiley   +1 more source

Prediction of hip joint function and analysis of risk factors for internal fixation failure after Femoral Neck System (FNS)

open access: yesBMC Musculoskeletal Disorders, 2023
Objective Analysis of the risk factors affecting hip function and complications after femoral neck system (FNS) surgery for femoral neck fractures is of great significance for improving the procedure’s efficacy.
Yazhong Zhang   +8 more
doaj   +1 more source

A Coaxial Bioprinted Hydrogel With Semipermeable Sheath and Pro‐Chondrogenic Core for Articular Cartilage Repair

open access: yesAdvanced Materials, EarlyView.
A sheath‐core biomimetic hydrogel is engineered with a compartmentalized yet integrated architecture for synergistic multifunctionality. Its stiff, semipermeable sheath mimics the ECM's load‐bearing and protective roles, encapsulating a soft core that provides a pro‐chondrogenic microenvironment similar to the PCM.
Zheyuan Shi   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy