Results 21 to 30 of about 175,324 (263)
Sistem Pengukuran Detak Jantung Janin Melalui Elektrokardiogram Abdominal dan Android
An android-based fetal heart rate measurement is presented in this article. The fetal heart rate was obtained from the mother's abdominal electrocardiogram which was then measured and processed by Raspberry pi using k-means.
Yusuf Anggara Aji +8 more
doaj +1 more source
Atypical fetal junctional ectopic tachycardia: a case report and literature review
Background Junctional ectopic tachycardia (JET) is caused by ectopic rhythms, originating in the atrioventricular node, typically with heart rate between 200 and 250 bpm. Herein, we present a case of fetal JET with normal fetal heart rate and a review of
Daisuke Katsura +6 more
doaj +1 more source
Fetal arrhythmias: Diagnosis and management
This article reviews important features for improving the diagnosis and management of fetal arrhythmias. The normal fetal heart rate ranges between 110 and 160 beats per minute.
Anjan S. Batra, Seshadri Balaji
doaj +1 more source
Music Modulates Autonomic Nervous System Activity in Human Fetuses
ContextFetal Autonomic Nervous sysTem Evaluation (FANTE) is a non-invasive tool that evaluates the autonomic nervous system activity in a fetus. Autonomic nervous system maturation and development during prenatal life are pivotal for the survival and ...
Francesca Massimello +8 more
doaj +1 more source
Improvements in fetal heart rate analysis by the removal of maternal-fetal heart rate ambiguities [PDF]
Misinterpretation of the maternal heart rate (MHR) as fetal may lead to significant errors in fetal heart rate (FHR) interpretation. In this study we hypothesized that the removal of these MHR-FHR ambiguities would improve FHR analysis during the final hour of labor.Sixty-one MHR and FHR recordings were simultaneously acquired in the final hour of ...
Pinto, Paula +4 more
openaire +2 more sources
Maternal, fetal and neonatal heart rate and heart rate variability in Holstein cattle
: The aim of this study was to describe the normal values for maternal, fetal and neonatal heart rate (HR) and heart rate variability (HRV) indexes in the time domain (standard deviation of beat-to-beat interval - SDNN; root mean square of successive ...
Dario A.C. Quevedo +5 more
doaj +1 more source
Background Maternal heart rate artefact is a signal processing error whereby the fetal heart rate is masked by the maternal pulse, potentially leading to danger by failure to recognize an abnormal fetal heart rate or a pre-existing fetal death.
Daniel J. Kiely +2 more
doaj +1 more source
Assessment and Management of Intrapartum Fetal Monitoring
This training session involves a didactic session and hands-on training sessions in the evaluation and management of intrapartum fetal heart rate patterns on a high-fidelity mannequin.
Michael Fialkow +4 more
doaj +1 more source
Introduction Non‐invasive fetal electrocardiography (NIFECG) has potential benefits over the computerized cardiotocography (cCTG) that may permit its development in remote fetal heart‐rate monitoring.
Becky Liu +2 more
doaj +1 more source
Fetal ECG Arrhythmia Detection Based on DensNet Transfer Learning
Purpose: The mortality rate of fetuses due to heart defects is a major concern for clinicians. The fetus's heart is monitored non-invasively using the abdominal Electrocardiogram (ECG) of the mother.
Ashutosh Singh +3 more
doaj +1 more source

