Using a Fiber Bragg Grating Sensor to Measure Residual Strain in the Vacuum-Assisted Resin Transfer Molding Process. [PDF]
Luo GM, Liou GY, Xiao HZ.
europepmc +1 more source
High‐pressure studies of the lead‐free hybrid organic–inorganic ferroelectric [N(C2H5)3CH3]FeCl4 demonstrate record low compressibility, establishing it as the least compressible molecular ferroelectric known. In situ diamond anvil cell experiments identify halide selection and inorganic sublattice tuning as key compressibility controls, advancing ...
Takeshi Nakagawa +11 more
wiley +1 more source
Analysis of Reliability of Strain Measurements Made with the Fiber Bragg Grating Sensor Rosettes Embedded in a Polymer Composite Material. [PDF]
Matveenko V +3 more
europepmc +1 more source
Upconversion nanoparticle photoluminescence was used to quantify heat burden during femtosecond direct laser writing of bioinks in real time. Transient temperature spikes above 120–140°C demonstrate the need for a stringent process optimization, and fast 20 µm/s scan speeds were established to maintain physiological conditions.
Amirbahador Zeynali +2 more
wiley +1 more source
Strain Transfer of Fiber Bragg Grating Sensor Externally Bonded to FRP Strip for Structural Monitoring after Reinforcement. [PDF]
Seo SY +5 more
europepmc +1 more source
Evaluation of prestress losses in concrete beams using destructive and non‐destructive methods
Abstract Over the past few decades, prestressing techniques have become essential in the construction of key structures, infrastructure, and bridges. The serviceability and safety of prestressed concrete (PC) elements are closely tied to the effectiveness of the prestressing process.
A. N. Consiglio, G. Muciaccia, G. Rosati
wiley +1 more source
Air Gap Fiber Bragg Grating for Simultaneous Strain and Temperature Measurement
We propose an air gap fiber Bragg grating (g-FBG) sensor that can measure strain and temperature simultaneously. The sensor is made by aligning two fiber Bragg gratings (FBGs), and an air gap exists between these two sub-gratings.
Fuling Yang +6 more
doaj +1 more source
Soft System Based on Fiber Bragg Grating Sensor for Loss of Resistance Detection during Epidural Procedures: In Silico and In Vivo Assessment. [PDF]
De Tommasi F +5 more
europepmc +1 more source
ABSTRACT The detection of partial discharges (PD) on the power transformer tank demands higher sensitivity in ultrasonic detection. To target the detection frequency band for sensor optimisation and enhance sensitivity, this paper presents a dual‐frequency sensitivity model for optical fibre ultrasonic sensors.
Sihan Wang +4 more
wiley +1 more source
Read My Leads: Subject‐Specific RF Hazard Assessment and Mitigation for DBS Implants in MRI
ABSTRACT Purpose To develop and validate a framework for personalized, implant‐specific MRI safety assessments using feedback from commercial deep brain stimulation (DBS) systems. To further use this framework to suppress RF‐induced heating with minimum compromise in imaging performance.
Berk Silemek +8 more
wiley +1 more source