Results 1 to 10 of about 233,406 (117)
Aseptic Failure of Tibial Components With Sleeves in Revision Total Knee Arthroplasty: A Novel Radiographic Assessment of Zonal Fixation. [PDF]
Background: Aseptic sleeve failure in revision total knee arthroplasty (TKA) is rare, and associated risk factors remain poorly understood. Shortcomings exist with current methods for assessing stem fill.
Colomb EL +5 more
europepmc +2 more sources
Experimental investigation of novel 18 multiturn multiplane pulsating heat pipe for methanol. [PDF]
A Pulsating Heat Pipe (PHP) is a wickless meandering capillary tube bent back and forth parallel to itself. In the present work, the possibility of employing a multiturn PHP as a pin-finned heat sink attached to a base plate is considered.
Babu NN, Narasimham GSVL, Srikrishna P.
europepmc +2 more sources
Transient thermal performance of constant fill ratio vapor chamber with different coolants
In this study, a constant fill ratio vapor chamber using water and ferrofluid as the coolants on the thermal performance and thermal optimization to provide the cooling range are presented.
Songkran WIRIYASART, Paisarn NAPHON
doaj +1 more source
This;paper;presents;the;effect;of;filling;ratio;on;thermal;performance;of;a;loop;thermosyphon. The experimental setup consists of an evaporator, a condenser, a riser and a downcomer. The dimensions of the loop thermosyphon under consideration were chosen
Samah Ihsan Adnan +2 more
doaj +3 more sources
Factors influencing power consumption and power-saving measures in ESR process [PDF]
Since the USA patent of electroslag remelting (ESR) metallurgy was held by P. K. Hopkins in 1940, the ESR technology has now entered a relatively mature stage after a 70-year history of development.
Yun-Long Xiong +2 more
doaj +1 more source
A review on pulsatin G heat pipes Latest research applicati ons And future scope
Heat pipes have become popular as passive heat diss ipation devices for many applications ranging from electronics to he at recovery in recent years. Pulsating Heat Pipe abbreviated as PHP is a n exclusive category of a heat pipe which does have wick ...
Chirag DAVE +5 more
doaj +1 more source
Does the Surgical Approach Influence the Canal Fill of the Proximal Femur for Hip Arthroplasty?
Background: Choosing the right size of the stem is crucial for uncemented hip arthroplasty. Undersizing can lead to early loosening, peri-prosthetic fracture due to femoral implant insertion, and/or osteointegration failure.
Lucas Mattesi, MD +5 more
doaj +1 more source
Heat and mass transfer for a small diameter thermosyphon with low fill ratio
Thermosyphons of smaller dimensions are more commonly sought after as electronics cooling devices. The interactions of the tube wall and working fluid become more significant as the dimension of a thermosyphon is reduced, particularly for high surface ...
Anthony J. Robinson +3 more
doaj +1 more source
Cytotoxic Effects of Bulk-Fill Composites on L929 Fibroblast Cells
Objective: Unlike traditional composite resins, bulk-fill composite resins could be polymerized as thicker layers. This study aims to contribute to the field by investigating the cytotoxic effects of various bulk-fill composite resins on L929 mouse ...
Numan Aydın +3 more
doaj +1 more source
The seismic resistance of existing embankments has become a significant issue as embankments fail frequently because of earthquakes. However, there are only a limited number of methods that can improve the seismicity of these existing embankments.
Takayuki Sakai +3 more
doaj +1 more source

