Results 181 to 190 of about 57,676 (259)

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Model for Calculating Impact Force for Individualized Hip Fracture Prediction During a Fall. [PDF]

open access: yesAdv Orthop
Agarwal A   +6 more
europepmc   +1 more source

Tunable Extraordinary Optical Transmission in the Long‐Wavelength Infrared Range Using Electrostatic MEMS Actuation

open access: yesAdvanced Materials Technologies, EarlyView.
A MEMS‐integrated metamaterial filter enables continuous, low‐voltage spectral tuning in the long‐wavelength infrared (LWIR). The device employs extraordinary optical transmission in a dual suspended metasurface stack, where electrostatic actuation precisely controls the intermembrane air gap.
Oleg Bannik   +6 more
wiley   +1 more source

Hierarchical Multi‐Material Architectures With Gradient Design for Dynamic‐Range Flexible Tactile Sensing

open access: yesAdvanced Materials Technologies, EarlyView.
Hierarchical multi‐material TPMS lattices are engineered as flexible tactile sensors by combining soft and stiff elastomeric layers with a conformal conductive coating. The bilayer architecture delivers sensitivity at low pressures while maintaining a broad detectable range under large loads, enabling reliable pressure and vibration monitoring for ...
Reza Noroozi   +3 more
wiley   +1 more source

Additive‐Manufactured, Multifunctional Bioreactor Technology for Dynamic Culture of 3D Bioprinted Tissue Models

open access: yesAdvanced Materials Technologies, EarlyView.
We introduce an additively manufactured bioreactor with a perfusion flow system and integrated temperature and pH sensors for skeletal muscle tissue biofabrication. The bioreactor's performance was evaluated by assessing the viability, spreading of the myoblast cells in a printed scaffold, and contraction of the isolated murine musculi interossei ...
Lys Sprenger   +9 more
wiley   +1 more source

Large Faraday Rotation in Liquid Crystals With Embedded Paramagnetic Ions (Cu2+, VO2+) at Room Temperature

open access: yesAdvanced Optical Materials, EarlyView.
Large Faraday rotation at room temperature is observed in thin films of discotic copper (Cu2+: 3d9) and vanadyl (VO2+: 3d1) enaminoketone complexes. The large Verdet constant originates from a high density of paramagnetic centers, metal‐ligand p−d hybridization and π orbitals involved in optical transitions (identified by DFT calculations), as well as ...
Karolina Łempicka‐Mirek   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy