Satisfaction evaluation of flash glucose monitoring system in early glucose management of patients after kidney transplantation [PDF]
AimTo study the effectiveness of the flash glucose monitoring (FGM) system in the monitoring of blood glucose in patients after renal transplantation.MethodsOne hundred and fifteen patients who underwent renal transplantation at the Renmin Hospital of ...
Jiayu Guo +11 more
doaj +4 more sources
Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis [PDF]
Cats with diabetic ketosis or ketoacidosis DK(A) require intensive glucose monitoring. The aim of this study was to assess the agreement between a portable blood glucose meter (PBGM) and a flash glucose monitoring system (FGMS; FreeStyle Libre 2.0 Abbott®
Jennifer S. Eiermann +5 more
doaj +4 more sources
Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications [PDF]
Xia Sheng, Ting Li, Yi Hu, Cheng-Shun Xiong, Ling Hu Department of Endocrine, The First Hospital of NanChang City, Nanchang, Jiangxi, 330008, People’s Republic of ChinaCorrespondence: Ling Hu, Email drhu_hl1172@163.comObjective: To discuss the ...
Sheng X, Li T, Hu Y, Xiong CS, Hu L
doaj +3 more sources
FreeStyle Libre Flash Glucose Monitoring system for people with type 1 diabetes in the UK: a budget impact analysis. [PDF]
INTRODUCTION: This study aims to estimate the budget impact of increased uptake of the FreeStyle Libre Flash Glucose Monitoring system in people with type 1 diabetes mellitus (T1DM) in the UK.
Blissett R +7 more
europepmc +2 more sources
Meta-Analysis of Average Change in Laboratory-Measured HbA1c Among People With Type 1 Diabetes Mellitus Using the 14 Day Flash Glucose Monitoring System [PDF]
AIM: FreeStyle Libre™ Flash Glucose Monitoring System (Flash GM), a novel, sensor-based, factory-calibrated system has been compared with self-monitoring of blood glucose in a well-controlled adult type 1 diabetes mellitus (T1D) population (HbA1c ≤ 7.5%,
Kirchmann, M +3 more
exaly +2 more sources
Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2TM in Healthy Women [PDF]
Continuous glucose monitoring (CGM) is used clinically and for research purposes to capture glycaemic profiles. The accuracy of CGM among healthy populations has not been widely assessed.
Zhuoxiu Jin +5 more
doaj +2 more sources
Continuous glucose monitoring and flash glucose monitoring systems are increasingly used by people with diabetes on multiple daily injections of insulin and continuous subcutaneous insulin infusion. Along with real-time updates on current glucose levels,
Peter Jennings +2 more
exaly +2 more sources
Glucose alarms approach with flash glucose monitoring system: a narrative review of clinical benefits [PDF]
Attaining an adequate glycemic control has been associated with a better prognosis and with a reduction in the risk of developing long-term microvascular and macrovascular diabetic complications.
Marcio Krakauer +9 more
doaj +2 more sources
The Impact of a Structured Education and Treatment Programme (FLASH) for People With Diabetes Using a Flash Sensor-Based Glucose Monitoring System: Results of a Randomized Controlled Trial [PDF]
Aims: Flash sensor-based glucose monitoring (FSGM) provides people with diabetes considerably more information on their glycaemic control. We have developed and evaluated a structured education and treatment programme, termed FLASH, to assist FSGM users ...
Melanie Schipfer +2 more
exaly +2 more sources
Evaluation of a flash glucose monitoring system in nondiabetic dogs with rapidly changing blood glucose concentrations [PDF]
Background A flash glucose monitoring system (FGMS; FreeStyle Libre) is useful for monitoring hypoglycemic dogs with diabetes. Objective To assess the utility of this FGMS in dogs with induced hypoglycemia and rapid fluctuations in blood glucose (BG ...
Leigh A. Howard +4 more
doaj +2 more sources

