Results 51 to 60 of about 5,098 (229)
ABSTRACT The problem of gas–solid interface charge accumulation is an important reason for distorting the surface electric field and then inducing surface discharge. The temperature gradient distribution formed on the spacer during the operation of a gas‐insulated transmission line (GIL) will aggravate the surface charge accumulation, further ...
Jianyi Xue +6 more
wiley +1 more source
Flashover at gas/insulator interface acts as a vital challenge to the safe and stable operation of gas-insulated system especially when involved with surface metallic particle.
Xiaolong Li, Chen Cao, Xin Lin
doaj +1 more source
Anode-Initiated Surface Flashover [PDF]
Either of two distinctively different surface flashover mechanisms may lead to the electrical breakdown of an insulator under high voltage stress in vacuum.
Anderson, R. A.
core
Mineral Oil‐Induced Ageing Characteristics of Aluminium Nitride‐Doped Silicone Rubber Nanocomposites
ABSTRACT Room temperature vulcanised (RTV) silicone rubber, commonly used as an external insulating coating on ceramic bushings of oil‐immersed transformers, undergoes significant degradation when exposed to mineral oil under harsh environmental conditions.
Dhanunjaya Naidu Vangapandu +6 more
wiley +1 more source
PCB layouts with different polygon shapes and insulation distances were prepared and their surface flashover voltage subjected to different ramping rates were measured at different temperatures and different low gas pressures for emulated high-altitude ...
Jierui Zhou +10 more
doaj +1 more source
Desenvolvimento e caracterização de filmes de materiais fracamente condutores depositados por magnetron sputtering para uso em isoladores elétricos de porcelana [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Ciência e Engenharia de Materiais.A Corrente de fuga superficial em isoladores de baixa e alta voltagem contribui com as perdas na ...
Teixeira, Jaime Domingos
core
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
The electrical performance of insulators under comprehensive conditions including low air pressure, pollution and icing, is an important basis for the selection of external insulation.
Bingbing Dong +5 more
doaj +1 more source
Post-Flashover Design Fires [PDF]
This report reviews the modelling of post-flashover fires and compares the various methods of predicting temperature versus time in post-flashover compartment fires, including the historical development of theoretical approaches.
Feasey, R
core +1 more source
Review of Catenary Icing on High‐Speed Railways: Characteristics, Impact and Countermeasures
ABSTRACT The pantograph–catenary system (PCS) is the only path for electrified railway trains to acquire energy. Catenary icing during winter is a common natural phenomenon, which usually leads to the deterioration of the current quality and severely affects the operational safety of trains.
Zheng Li +7 more
wiley +1 more source