Results 31 to 40 of about 6,358 (219)
Displacement Current and Surface Flashover [PDF]
High-voltage vacuum insulator failure is generally due to surface flashover rather than insulator bulk breakdown. Vacuum surface flashover is widely believed to be initiated by a secondary electron emission avalanche along the vacuum-insulator interface.
G. J. Caporaso +7 more
core +1 more source
The discharge and flashover phenomenon of post insulators in rainy weather has not been given sufficient consideration; however, with the construction of ultra-high voltage power grids, the performance of the external insulation and the ability to ...
Yuxi Dong +7 more
doaj +1 more source
AC Flashover Performance of 10 kV Rod-Plane Air-Gapped Arresters under Rain Conditions
According to operational experience of power systems, the outdoor insulation strength can be reduced due to the effect of rain. Till now, little work has been done to investigate the flashover performance of air gapped arresters under rain conditions ...
Jiazheng Lu +4 more
doaj +1 more source
Development of Flame Retarded Battery Casings Using Glass Fiber‐Reinforced Epoxy Resin
Development of flame retarded battery casings using glass fiber‐reinforced epoxy resin by exploiting the synergistic action of APP and TiO2 to promote the formation of a coherent ceramic‐phosphate char layer. ABSTRACT This study investigates the development of glass fiber‐reinforced epoxy resin composites with enhanced fire performance for application ...
Ákos Pomázi +4 more
wiley +1 more source
Experience shows that under unidirectional wind or certain terrain, the surface of post insulators is non-uniformly polluted between windward and leeward sides, which affects the flashover characteristics.
Zhijin Zhang +5 more
doaj +1 more source
Fire Testing and Hazard Assessment for Flame Retardant Polymer Composites
Flame retardant polymer composites are now being evaluated with more than pass or fail flammability tests. Heat release, smoke, toxicity, and system‐level behavior are receiving more attention, and multi‐scale methods are being used to describe fire hazard under more realistic conditions.
Shuheng Wang +8 more
wiley +1 more source
Enhancing flashover strength along oil/pressboard interface using nanofluids
One of the weakest paths for electrical discharge in power transformers is oil/pressboard interface. So, in this study it is aimed to enhance the flashover resistance of such interface through using the concept of nanofluids.
El-Sayed M. El-Refaie +3 more
doaj +1 more source
Polypropylene (PP) with low leakage current and high mechanical strength is a promising candidate for recyclable vacuum insulation applications, but its surface flashover voltage is low. Advantageously to widely used technologies such as fluorination and
Kong, Fei +8 more
core +1 more source
Predicting Flashover Occurrence using Surrogate Temperature Data
Fire fighter fatalities and injuries in the U.S. remain too high and fire fighting too hazardous. Until now, fire fighters rely only on their experience to avoid life-threatening fire events, such as flashover.
Fu, Eugene Yujun +7 more
core +1 more source
Effecft of co‐doping polyaniline with phosphoric acid and phytic acid on the heat release rate of polyethylene. Abstract Polyolefins, such as polyethylene (PE), are highly flammable and electrically insulative, limiting their applicability. The study explored the flame‐retardancy and electrical conductivity of PE/polyaniline (PE/PANI) nanocomposites ...
Akeem Adisa +4 more
wiley +1 more source

