Results 1 to 10 of about 6,536 (165)
Through spatial electric field monitoring, it is expected to realize insulator pollution condition monitoring and contamination flashover warning in a non-contact way.
Dongdong Zhang +6 more
doaj +3 more sources
Defect Identification of Composite Insulator Based on Infrared Image. [PDF]
Zhang Z +4 more
europepmc +2 more sources
Performance Investigation on Different Designs of Superhydrophobic Surface Texture for Composite Insulator. [PDF]
Zhao M +5 more
europepmc +2 more sources
Effect of Silicone Rubber of a Waste Composite Insulator on Cement Mortar Properties. [PDF]
Qin G +5 more
europepmc +2 more sources
Research on Defect Detection Technology of Composite Insulator Sheath [PDF]
The composite insulator sheath plays an important role in protecting the core rod and insulation. The thickness of the sheath must meet the corresponding standard requirements.
Li Wenbo +7 more
doaj +1 more source
Cause analysis on fracture of a 500 kV composite insulator
In order to study the cause of wire falling accident caused by fracture of 500 kV composite insulator in the no-fly zone of a province, various inspections and tests were carried out on the accident insulator string according to the current standard. The
LI Bocheng +6 more
doaj +1 more source
Mechanical Behavior of Crimping Composite Post Insulator: Experimental and Simulation Study
The composite post insulator composed of a large diameter mandrel and flange pressed by a one-time integral pultrusion has high strength and good toughness and is widely used in the existing flexible converter valve.
Jin Xiao +4 more
doaj +1 more source
Analysis of the influence of glued flange joint damage on dynamic properties of composite insulator
In order to explore the relationship between glued flange joint damage and the change of dynamic characteristics of composite insulator bushing, the paper takes a ± 800 kV composite insulator as the research object and establishes the finite element ...
DI Yuelun +3 more
doaj +1 more source
The installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to
Kalaiselvi Aramugam +4 more
doaj +1 more source
Pollution Flashover Characteristics of Composite Crossarm Insulator with a Large Diameter
The composite crossarm insulator differs greatly from the suspension insulator in structure and arrangement. This study aims to determine the pollution flashover characteristics of composite crossarm insulators under different voltage grades.
Jing Nan +4 more
doaj +1 more source