Results 1 to 10 of about 5,098 (229)

Enhancing flashover strength along oil/pressboard interface using nanofluids

open access: yesAlexandria Engineering Journal, 2020
One of the weakest paths for electrical discharge in power transformers is oil/pressboard interface. So, in this study it is aimed to enhance the flashover resistance of such interface through using the concept of nanofluids.
El-Sayed M. El-Refaie   +3 more
doaj   +1 more source

Development of ± 550 kV DC GIS Basin Insulator

open access: yesHigh Voltage, EarlyView.
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao   +9 more
wiley   +1 more source

Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects

open access: yesHigh Voltage, EarlyView.
ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its
Gaoyi Shang   +6 more
wiley   +1 more source

Study on Influencing Factors of Insulators Flashover Characteristics on the 110 kV True Tower Under the Lightning Impulse

open access: yesIEEE Access, 2018
Lightning strike is the main reason for the transmission line tripping. Studies on the insulator flashover characteristics and the accurate flashover criteria under the lightning impulse are the basis for correctly evaluating the lightning resistance ...
Yongxia Han   +7 more
doaj   +1 more source

Study of Positive Corona Discharge of Needle Plate Electrodes in Airflow

open access: yesHigh Voltage, EarlyView.
ABSTRACT For high‐speed moving objects such as aircraft and wind turbine blades, discharge occurs under strong airflow. Research on lightning attachment characteristics has been extensive, whereas the role of corona discharge in pre‐breakdown streamer development has received less attention.
Lei Lan   +6 more
wiley   +1 more source

AC Surface Flashover and Gas Generation Difference of the Cellulose Insulation Pressboard Immersed in Novel 3-Element Mixed Oil and Mineral Oil

open access: yesIEEE Access, 2019
Surface flashover fault is one of the most challenge issues in oil-cellulose insulation pressboard system used in power transformer. In this study, a comparative study of the AC surface flashover properties of the novel 3-element mixed oil-cellulose ...
Xin Chen   +5 more
doaj   +1 more source

Impulsive Flashover Characteristics and Weibull Statistical Analysis of Gas-Solid Interfaces With Varying Relative Humidity

open access: yesIEEE Access, 2020
This paper informs on the flashover strength of three materials: Delrin (polyoxymethylene), HDPE (high-density polyethylene) and Ultem (polyetherimide) with smooth surface finishes, in zero-grade air at -0.5, 0 and 0.5 bar gauge, and at <; 10%, ~50 ...
Ruairidh W. Macpherson   +4 more
doaj   +1 more source

Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China

open access: yesHigh Voltage, EarlyView.
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li   +9 more
wiley   +1 more source

The synergistic effect of micro structure/nanofiller/superhydrophobicity on the surface flashover

open access: yesHigh Voltage, 2022
The surface flashover is affected by many factors, such as surface roughness, nanofillers and chemical functional groups. In this research study, polyamide mesh was utilised as a scaffold to systematically study the synergistic effect of micro structure ...
Qing Xie   +6 more
doaj   +1 more source

Performance Evaluation of Outdoor High Voltage Glass Insulators in High Pollution Industrial Areas Using Simulated Acid Rain Contamination

open access: yesIEEE Access, 2022
A suitable, non-standard method for artificial pollution testing using simulated acid rain pollution in a laboratory was developed in this work. The method is applicable to a wide range of climatic conditions and rain acidities.
Chibuike Ilomuanya   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy