Results 21 to 30 of about 6,358 (219)
This study focuses on the feature extraction and classification of surface discharges of ice-covered insulator strings during process of alternating current flashover.
Yong Liu +3 more
doaj +1 more source
Unraveling the “U-Shaped” Dependence of Surface Flashover Performance on the Surface Trap Level
The effects of surface traps on surface flashover remain controversial. To clarify the relation between surface flashover and surface trap level, in this work, the surface trap level of epoxy composites was modified by nanoparticles incorporation ...
Shengtao Li +6 more
doaj +1 more source
Flashover Performance and Process of Suspension Insulator Strings Artificially Covered with Snow
Snow accumulates on the surface of insulator string, causing a decrease in its electrical performance, seriously threatening the reliable operation of the power grid.
Yuyao Hu +5 more
doaj +1 more source
The anti-pollution flashover characteristic of composite insulators is the main indicators to evaluate their electrical performance, and the pollution flashover voltage can directly characterize the anti-pollution flashover characteristics of the ...
Wei Wang +7 more
doaj +1 more source
The Effect of a Vertical Electric Field on the Surface Flashover Characteristics of a Bushing Model
High-voltage bushings play a crucial role in energy conveyance. Their specialized electric structure makes the bushing more vulnerable to surface discharge.
Mingxi Zhu +5 more
doaj +1 more source
Optimized Design of Shed Parameters for Polluted Hollow Porcelain Insulators at High Altitude
The pollution flashover problem of hollow insulators, one of the primary faults in substations, can be improved by optimizing the shed parameters. Combining the artificial pollution test and electric field simulation, this paper studies the optimal shed ...
Ziwei Qiu +9 more
doaj +1 more source
Effects of surface roughness on DC and AC surface flashover performances of epoxy composites in SF6/N2 mixtures [PDF]
Surface flashover of the epoxy insulator is one of the urgent insulation issues in SF6/N2 filled gas-insulated equipment, causing irreversible insulation failure and harming the secure operation of power systems. However, the effects of surface roughness,
Lei Zhang +9 more
doaj +1 more source
Wet Snow Flashover Characteristics of 500-kV AC Insulator Strings with Different Arrangements
In order to study the wet snow flashover characteristics of 500-kV AC insulator strings under different arrangements, wet snow flashover tests were carried out in the large climate chamber of China Electric Power Research Institute (CEPRI).
Jingwei Xu +7 more
doaj +1 more source
The flashover performance of insulators is the foundation of the calculation of precise lightning protection. The material and structure of an insulator affect its flashover performance but the research on the differences in the flashover performance of ...
Yaqi Zhang +9 more
doaj +1 more source
Simulation Experiment on Discharge of Plastic Film Overlapping on UHVDC Transmission Lines
In order to study the discharge phenomena of plastic film overlapping on UHV DC transmission lines and explore the cause of flashover fault of a ± 800 kV UHV line, an experimental study is conducted on the flashover characteristics of plastic film with ...
Shenghui WANG +3 more
doaj +1 more source

