Results 1 to 10 of about 1,026,977 (295)

Comparison of natural contamination accumulation characteristics between composite rod insulators and standard suspended insulator strings

open access: yesThe Journal of Engineering, 2018
In order to attain the pollution characteristics difference between composite rod insulators and standard disc-type suspended insulator which is critical to the insulation selection of transmission line, pollution accumulated on composite rod insulators ...
Li Te   +5 more
doaj   +2 more sources

Discussion on infrared accurate temperature-measuring technology of composite insulators for overhead lines

open access: yesThe Journal of Engineering, 2019
Through analysing the infrared temperature measurement data obtained from composite insulators for overhead lines in actual operation state and atmospheric environment, detection requirements of infrared accurate temperature-measuring technology of ...
Rong Liu   +5 more
doaj   +2 more sources

Global experience of HVDC composite insulators in outdoor and indoor environment

open access: yesReviews on Advanced Materials Science, 2020
High-voltage direct current (HVDC) transmission is known as green-energy transfer technology and has recently become an attractive alternative of high-voltage alternating current (HVAC) due to its high-power transmission capability and lower power loss ...
Akbar Mohammad, Mehmood Basharat
doaj   +2 more sources

Prediction Model for the DC Flashover Voltage of a Composite Insulator Based on a BP Neural Network

open access: yesEnergies, 2023
To be able to predict the DC flashover characteristics of composite insulators, a four-layer BP neural network model is established with composite insulator shed structure parameters as the input. Three algorithms (gradient descent with momentum, RMSProp
Zhenan Zhou   +3 more
doaj   +1 more source

Study on the calculation of shielding failure for dc transmission lines

open access: yesThe Journal of Engineering, 2019
Lightning is the main cause of transmission line failure, and it is important to improve the lightning protection level of the transmission line for the stability of the power system.
Jinbo Wu   +5 more
doaj   +1 more source

An Optimized Infrared Detection Strategy for Defective Composite Insulators According to the Law of Heat Flux Propagation Considering the Environmental Factors

open access: yesIEEE Access, 2018
Composite insulators have been extensively adopted in electric transmission lines due to their preferable resistance to contamination flashover. To generally ensure the function of power networks, it is of crucial importance to perform regular online ...
Li Cheng   +3 more
doaj   +1 more source

Research of cycloaliphatic epoxy resin and silicone rubber composite insulator interface based on four‐electrode system and temperature rise model

open access: yesHigh Voltage, 2023
Interface degradation between mandrel and sheath can cause a decrease in insulation performance and mechanical strength of composite insulators. In this study, the interface ageing properties of cycloaliphatic epoxy resin and silicone rubber composite ...
Yunsong Wang   +4 more
doaj   +1 more source

Study on the influence mechanism of ambient humidity on the temperature rise of decay‐like composite insulators

open access: yesHigh Voltage, 2022
At present, observing the temperature rise of composite insulators is an effective method for the detection of decay‐like defects. However, ambient humidity will affect the temperature rise of composite insulators, which will cause problems in screening ...
Zheng Zhong   +4 more
doaj   +1 more source

Fiber Bragg grating monitors for thermal and stress of the composite insulators in transmission lines

open access: yesGlobal Energy Interconnection, 2018
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines.
Heming Deng   +5 more
doaj   +1 more source

Dry band formation mechanism of composite insulator with generalized finite difference-time domain

open access: yes电力工程技术, 2022
The pollution flashover of composite insulators is mainly the flashover caused by alternate occurrence of arc development and dry band formation. At present, researchers have investigated the development of insulator arc along the surface.
HE Jiahong, DONG Bowen, HE Kang
doaj   +1 more source