Results 31 to 40 of about 5,040 (292)
Optimization of the structure of insulating composite materials
The article deals with the interdependent relationship between the properties of a structure and the properties of a material, which sets the task of reducing them, even they are indistinguishable, to a certain integrity. The object of research and analysis in the article is a building structure, which is seen as an open self-organized complex ...
Kos, Zeljko +5 more
openaire +4 more sources
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines.
Heming Deng +5 more
doaj +1 more source
At present, observing the temperature rise of composite insulators is an effective method for the detection of decay‐like defects. However, ambient humidity will affect the temperature rise of composite insulators, which will cause problems in screening ...
Zheng Zhong +4 more
doaj +1 more source
The electrical performance of insulators under comprehensive conditions including low air pressure, pollution and icing, is an important basis for the selection of external insulation.
Bingbing Dong +5 more
doaj +1 more source
Dry band formation mechanism of composite insulator with generalized finite difference-time domain
The pollution flashover of composite insulators is mainly the flashover caused by alternate occurrence of arc development and dry band formation. At present, researchers have investigated the development of insulator arc along the surface.
HE Jiahong, DONG Bowen, HE Kang
doaj +1 more source
Testing Method for Composite Insulators Interface Based on Nonlinear Ultrasonic
The interface is the weakness of composite insulators. As the interface bonding fails, the uniform distribution of electric field will be affected, which accelerates the aging of composite insulators and affects the safe operation of transmission lines ...
Sida Zhang +4 more
doaj +1 more source
Full-Scale Testing on Seismic Performance of Surge Arrester with Retrofitted Composite Insulators
In electrical substations, glass-fibre reinforced polymer (GFRP) insulators provide an alternative to porcelain insulators for better seismic performance.
Sheng Li +5 more
doaj +1 more source
Enzymes of the 2‐hydroxyacyl‐CoA lyase group catalyze the condensation of formyl‐CoA with aldehydes or ketones. Thus, by structural adaptation of active sites, practically any pharmaceutically and industrially important 2‐hydroxyacid could be biotechnologically synthesized. Combining crystal structure analysis, active site mutations and kinetic assays,
Michael Zahn +4 more
wiley +1 more source
ABSTRACT Objective Stereoelectroencephalography‐guided radiofrequency thermocoagulation (SEEG‐RFTC) has emerged as a safe and effective minimally invasive treatment for children with drug‐resistant focal epilepsy. Although evidence from real‐world studies remains limited, numerous pediatric cases have demonstrated promising outcomes. This retrospective
Weitao Chen +7 more
wiley +1 more source
Composite insulators are widely used in modern power systems to provide electrical insulation and mechanical support for transmission lines and substations.
Jiazheng Lu +4 more
doaj +1 more source