Results 71 to 80 of about 3,838,132 (157)

Case Report: Application of the LVIS stent as a bridging device for salvage treatment of malapposed lattice flow diverter in a giant posterior circulation aneurysm: technical note and clinical efficacy

open access: yesFrontiers in Surgery
ObjectiveTo evaluate the feasibility, technical nuances, and clinical outcomes of using the LVIS stent as a bridging device for the salvage treatment of a malapposed Lattice flow diverter (FD) in a giant posterior circulation aneurysm.MethodsWe present a
Musheng Rao, Guan Lin, Shuzhou Cai
doaj   +1 more source

A 7‐mm Covered TIPS Reduces Hepatic Encephalopathy Without Increasing Rebleeding in Cirrhotic Patients With Small Liver: A Randomized Study

open access: yesLiver International, Volume 46, Issue 10, October 2026.
ABSTRACT Background/Aims International guidelines recommend initiating transjugular intrahepatic portosystemic shunt (TIPS) placement with an 8‐mm stent. However, there is an evident lack of randomized controlled trials evaluating TIPS diameters < 8 mm in cirrhotic patients with a relatively small liver. The aim of this study was to determine whether 7 
Fuquan Liu   +17 more
wiley   +1 more source

Case Report: “Stent-within-a-Stent” technique after telescopic flow diverter reconstruction for basilar artery aneurysm with proximal stenosis

open access: yesFrontiers in Surgery
BackgroundComplex basilar artery aneurysms are challenging to treat due to their deep anatomical location and proximity to critical perforating arteries, as well as their frequent fusiform morphology and association with long-segment stenosis or ...
Iroda Mammadinova   +5 more
doaj   +1 more source

Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models [PDF]

open access: yesUltrasonography, 2015
Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods:
Anderson Chun On Tsang   +7 more
doaj   +1 more source

Bioinspired Passive Flow Routing to Mitigate Thrombosis in Prosthetic Heart Valves and Cardiovascular Devices

open access: yesAdvanced Science, Volume 13, Issue 53, 24 September 2026.
Bioinspired passive flow routing mitigates thrombosis in cardiovascular devices by redirecting a small fraction of forward flow into stagnation‐prone regions. Inspired by avian alula and aircraft slat mechanisms, strategically placed routing channels restore washout around mechanical heart valves, reducing low‐shear exposure by four orders of magnitude
Yevgeniy Kreinin   +8 more
wiley   +1 more source

Posterior Circulation Aneurysmal Subarachnoid Hemorrhage: A Comparison Between Saccular and Dissecting Aneurysms

open access: yesBrain and Behavior, Volume 16, Issue 9, September 2026.
ABSTRACT Background There is a lack of comparative studies between posterior circulation saccular aneurysms (SA) and dissecting aneurysms (DA). This study aims to comprehensively compare the clinical characteristics, treatment strategies, and outcomes of SA and DA.
Jian Li   +10 more
wiley   +1 more source

Flow-Diverter Stent for an Unruptured Aneurysm at the Junction of the Internal Carotid Artery and Persistent Primitive Trigeminal Artery: Case Report and Literature Review

open access: yes, 2019
BACKGROUND: Persistent primitive trigeminal artery (PPTA), which is a fetal carotid-basilar anastomosis, is the most common embryologic vascular remnant persisting in adults. Aneurysms can arise between the internal carotid artery (ICA) and PPTA. Here we
Ito, Takeo   +7 more
core   +1 more source

Coil migration through two flow-diverting stents

open access: yesBMJ Case Reports
We report a case of a patient who initially presented with a subarachnoid haemorrhage secondary to a ruptured supraclinoid internal carotid artery (ICA) blister aneurysm. The patient was treated successfully with a flow diverter stent (FD) and coiling; however, a large aneurysm recurrence via a feeding posterior communicating artery (PCOM) was noted on
Rogers, Patrick Scott   +3 more
openaire   +2 more sources

Hydrodynamic Resistance of Intracranial Flow-Diverter Stents: Measurement Description and Data Evaluation [PDF]

open access: yesCardiovascular Engineering and Technology, 2019
Abstract Purpose Intracranial aneurysms are malformations forming bulges on the walls of brain arteries. A flow diverter device is a fine braided wire structure used for the endovascular treatment of brain aneurysms. This work presents a rig and a protocol for the measurement of the hydrodynamic resistance of flow diverter stents.
Benjamin Csippa   +4 more
openaire   +4 more sources

A Forgotten Cause of Chronic Dizziness in the Elderly: Exercise‐Induced Vertebrobasilar Insufficiency due to Grade III Subclavian Steal Syndrome

open access: yesClinical Case Reports, Volume 14, Issue 9, September 2026.
ABSTRACT Chronic dizziness in elderly patients, particularly when reproducibly triggered by upper limb exertion, should prompt evaluation for arm‐exertion‐provoked vertebrobasilar hypoperfusion due to subclavian steal syndrome. Duplex ultrasonography can identify complete retrograde vertebral artery flow and confirm complete Grade III subclavian steal ...
Said Abdirahman Ahmed   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy