Results 161 to 170 of about 219,307 (309)

Transcranial Pulse Stimulation Enhances Dexterity in Parkinson's Disease: A Randomized Sham‐Controlled Trial

open access: yesMovement Disorders, EarlyView.
Abstract Background Ultrasound‐based neuromodulation, capable of reaching deep brain areas with high precision, represents cutting‐edge technology in non‐invasive brain stimulation and is investigated as a novel treatment for neurological and psychiatric disorders, including Parkinson's disease (PD).
Eva Matt   +14 more
wiley   +1 more source

Four Directions, One Solution: Enabling Rapid Diffusion Tensor MRI for Ultra‐Low Field Using Deep Learning

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This study revisits the tetrahedral encoding strategy originally proposed to accelerate Diffusion Tensor Magnetic Resonance Imaging (DT‐MRI) by reducing the requisite number of diffusion‐weighted measurements to four. We examine its practical limitations and explore how artificial intelligence (AI) can extend its utility. Specifically,
Joshua Mawuli Ametepe   +4 more
wiley   +1 more source

ALTERNATING SSFP PERMITS RAPID, BANDING-ARTIFACT-FREE BALANCED SSFP FMRI

open access: yes, 2013
Blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) is the dominant tool used for mapping human brain function because it is non-invasive, does not use ionizing radiation, and offers relatively high spatial and ...
Patterson, Steve
core  

Ultrafast fMRI Detects Age‐Related Changes in Harmonics of Cardiac Pulsations in the Brain at 7 T

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Aging impacts pulsatility of blood vessels in the brain, reflecting vascular health. Resolving characteristics of cardiac pulsatility requires faster acquisitions than traditional fMRI. An ultrafast fMRI method was developed and applied to sample several harmonics of cardiac pulsations at 7 T.
Charles Marchini   +5 more
wiley   +1 more source

Single‐Shot 2D Radial Echo Planar Imaging for Functional MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a novel single‐shot radial echo planar imaging (ss‐rEPI) technique for rapid, distortion‐free brain imaging in functional MRI experiments. Methods Radial multi‐gradient echo (radial mGRE) data were acquired on a 3T clinical scanner using a 2D ss‐rEPI readout with small golden‐angle rotations between echoes.
Christoph A. Rettenmeier   +4 more
wiley   +1 more source

Quantifying Cardiac, Respiratory, and Low Frequency Components of CSF Motion From fMRI Inflow Effects

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Cerebrospinal fluid (CSF) flow oscillations have emerged as a potentially important marker related to brain clearance, but their acquisition often relies on specialized imaging MRI sequences. The purpose of this work was to enable quantitative assessment of CSF flow associated with cardiac, respiratory, and low‐frequency cycles using ...
Pontus Söderström   +5 more
wiley   +1 more source

Memory accuracy : A 7-Tesla fMRI approach to memory accuracy ; retrieval, monitoring and control processes

open access: yes, 2010
Risius U-M. Memory accuracy : A 7-Tesla fMRI approach to memory accuracy ; retrieval, monitoring and control processes.
Risius, Uda-Mareke
core  

TRACC‐PHYSIO: Time‐Domain Resolution‐Aligned Cross‐Correlation to Estimate PHYSIOlogical Coupling and Time Delays in Dynamic MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To validate a method to assess cardiac and respiratory brain pulsations in slowly sampled dynamic MR scans. Cardiac and respiratory pulsations are key drivers of neurofluid circulation. However, resolving their temporal dynamics requires fast imaging, which is not achievable in many dynamic MR acquisitions.
Adam M. Wright   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy