7-year follow-up after open reduction and internal screw fixation in Bennett fractures [PDF]
Background: Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint.
Bignion, Dietmar +6 more
core
The management of segmental tibial shaft fractures: A systematic review. [PDF]
INTRODUCTION: Segmental tibial fractures are complex injuries associated with significant soft tissue damage that are difficult to treat. This study aimed to identify the most effective method of treating segmental tibial fractures.
Hing, CB +4 more
core +1 more source
Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review [PDF]
Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems ...
Kalová, Martina +5 more
core +1 more source
Thinner Tibial Spine Fracture Fragments Are Associated With Risk of Fixation Failure
Purpose: To determine the rate of and risk factors for failure of tibial spine fracture (TSF) repair. Methods: This was a retrospective review of patients aged 18 years or younger with TSF who underwent arthroscopic repair performed by a single ...
Gregory Benes, B.S. +3 more
doaj +1 more source
Biepicondylar fracture presenting with elbow dislocation: a case report
Introduction Biepicondylar fracture of the elbow is very rare, and to date there have only been three reports of this injury and its treatment in the English scientific literature.
Guner Savas +5 more
doaj +1 more source
Background Comparison of 4 cannulated lag screws (3 inverted triangular cannulated screws + anti-rotating screws;4 CLS), dynamic hip screws + derotational screws (DHS + DS), and femoral neck fixation system (FNS) in the treatment of Biomechanical ...
Ji Ma +4 more
doaj +1 more source
Construct failure after open reduction and plate fixation of displaced midshaft clavicular fractures [PDF]
Introduction: Worldwide, implants mostly used for fixation of displaced midshaft clavicular fractures (DMCF) are the easily to bend reconstruction plate and the stiffer small fragment locking compression plate.
Heijden, F.H.W.M. (Frank) van der +3 more
core +4 more sources
Background Total hip arthroplasty (THA) is the treatment of choice for posttraumatic arthritis with failed internal fixation for hip fractures. However, the postoperative prognosis is not clear.
Ching-Chieh Hung +4 more
doaj +1 more source
Mechanical properties of a degradable phosphate glass fibre reinforced polymer composite for internal fracture fixation [PDF]
NOTICE: this is the author’s version of a work that was accepted for publication in Materials Science and Engineering. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality ...
Brauer, DS, Kobayashi, HYLS, Russel, C
core +1 more source
Incidence of Corrective Procedures After Nonoperatively Managed Distal Radius Fractures in the Elderly. [PDF]
Although the majority distal radius fractures in the elderly are initially managed nonoperatively, the true incidence of subsequent corrective surgery is unknown.
Immerman, Igor +3 more
core

