Results 71 to 80 of about 173,282 (180)
Oblique multi-periscopic prism for field expansion of homonymous hemianopia
Oblique Fresnel peripheral prisms have been used for field expansion in homonymous hemianopia mobility such as walking and driving. However, limited field expansion, low image quality, and small eye scanning range limit their effectiveness.
Nish Mohith Kurukuti (14440461) +9 more
core +1 more source
<p><strong>Prism: Multiple spline regression with regularization, dimensionality reduction, and feature selection</strong></p> <p>Prism uses a combination of statistical methods to conduct spline-based multiple regression ...
Christopher Madan (5267350) +1 more
core +1 more source
Determination of Optical Constants in the Mid-Infrared Spectral Range by use of the Attenuated Total Reflection Method [PDF]
Infrared (IR) spectroscopy is one of the most useful experimental methods in the investigation of hydrogen-bonded systems. However, application of transmission IR spectroscopy to aqueous systems is only of limited value due to the very strong water ...
Biliškov, N:
doaj
. Prism coupling in the Otto configuration is a well-known method for excitation of surface plasmon polaritons in a metal film in the classical planar three-layered geometry consisting of optical prism, intermediate medium (air) and metal surface (thick ...
H Y Stoyanov
core
A concentrator system for BI-CPVT with static linear Fresnel lenses [PDF]
A greenhouse with Fresnel lenses in the south facing roof and a receiver for concentrated Photovoltaic with water cooling (CPVT system) will result in electrical and thermal energy output from the solar energy excess entering a greenhouse.
Swinkels, G.L.A.M. +4 more
core
Strabismus Responsive to Fresnel Prisms Therapy Before Surgery
【目的】両眼視が失われていた手術予定の斜視患者にフレネル膜プリズムによる保存的治療を行い、両眼視機能の改善が得られた2症例を報告する。【症例】症例1は5歳女児。2歳頃から内斜視で、他院で眼鏡により経過観察されていたが、軽快せず3歳時に当科を受診した。眼位は完全屈折矯正眼鏡装用にて遠見、近見とも45ΔETで、同時視は認められなかった。手術までの期間、右20Δ基底外方、左15Δ基底外方のフレネル膜プリズム療法を施行したところ、両眼視機能が得られ、斜視角の減少を認めた。症例2は9歳男児。2歳半から母親は眼位異常に気づいていたが、近医で経過観察と指示され9歳時に当科を受診した。眼位はAPCTで近見30ΔXT、DVDを合併していた。同時視認められず恒常性外斜視と診断した ...
Aihara, Chigusa +6 more
openaire +2 more sources
Refraction and total reflection of microwaves by a prism
A description of several experiments carried out to investigate the behaviour of 3.2 cm. microwaves on passing through a dielectric prism is given in this thesis.
Kneeland, David Randolph
core +1 more source
Saturnian Irregular Satellites as a Probe of Kuiper Belt Surface Evolution
We present the JWST NIRSpec PRISM 0.7–5.3 μ m spectra of Albiorix and Siarnaq and the NIRSpec G235H/G395M 1.7–5.3 μ m spectra of Phoebe, the three largest Saturnian irregular satellites.
Matthew Belyakov, Michael E. Brown
doaj +1 more source
Performance Modeling of Fresnel-Based CPV Systems: Effects of Deformations under Real Operation Conditions [PDF]
Getting a lower energy cost has always been a challenge for concentrated photovoltaic. The FK concentrator enhances the performance (efficiency, acceptance angle and manufacturing tolerances) of the conventional CPV system based on a Fresnel primary ...
Mohedano del Pozo, Raúl +9 more
core
Fresnel diffractive imagery arrays : ground-based validation and space applications [PDF]
L'imageur de Fresnel est un instrument focalisation diffractive qui est développé pour l'observation astrophysique depuis l'espace. Il est a longue focale, et de ce fait requiert le vol en formation.
Raksasataya, Truswin
core

