Results 1 to 10 of about 11,309,232 (75)
The advance in energy-sensing and smart-meter technologies have motivated the use of a Non-Intrusive Load Monitoring (NILM), a data-driven technique that recognizes active end-use appliances by analyzing the data streams coming from these devices.
Anthony Faustine, Lucas Pereira
doaj +4 more sources
Забезпечення якості електричної енергії потребує комплексного підходу до проектування та вибору фільтрокомпенсуючих та симетруючих пристроїв. На підставі аналізу відомих робіт встановлено, що формування струму фільтру здійснюється за алгоритмом в основі ...
R. V. Vlasenko, O. V. Bialobrzeski
doaj +4 more sources
АДАПТИВНЕ УПРАВЛІННЯ РЕЛЕЙНИМ РЕГУЛЯТОРОМ ТРИФАЗНОГО СИЛОВОГО АКТИВНОГО ФІЛЬТРА
Current control relay of three-phase active power filter provides the toggle power switches, when the current error exceeds a fixed value (hysteresis band), while the frequency of setting options is variable.
R. V. Vlasenko, O. V. Bialobrzeski
doaj +2 more sources
СURRENT FILTERING IN A THREE-PHASE THREE-WIRE POWER SYSTEM AT ASYMMETRIC SINUSOIDAL VOLTAGES [PDF]
Purpose. Investigation of the optimal current distribution between source, shunt active filter and reactive compensator of a three-phase three-wire system that provides consumption of a sinusoidal symmetric current under asymmetric source voltages with ...
M. Yu. Artemenko +2 more
doaj +3 more sources
Determination of Inactive Powers in a Single-Phase AC Network [PDF]
Based on the development of the theory of reactive power and distortion power, starting with the works of Fryze and Budeanu, it has been found that the contradictions in the definition of the components of inactive powers are caused by errors in the ...
Nickolay I. Shchurov +6 more
doaj +2 more sources
Phase Coordinate System and p-q Theory Based Methods in Active Filtering Implementation
This paper is oriented towards implementation of the main theories of powers in the compensating current generation stage of a three-phase three-wire shunt active power system.
POPESCU, M., BITOLEANU, A., SURU, V.
doaj +2 more sources
Control of disturbing loads in residential and commercial buildings via geometric algebra. [PDF]
Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component.
Castilla MV.
europepmc +2 more sources
Study of three-phase active power filter operation using non-sinusoidal voltage
The active power filter designed to compensate inactive power components. Aim: The aim of the study is to assess the quality of the three-phase active power filter in the distortion of the mains voltage supply, which is caused by the influence of non ...
Руслан Володимирович Власенко +1 more
doaj +7 more sources
Purpose. Development and theoretical ground of the analytical method for the calculation of the active, reactive and total powers in the electric traction devices, taking into consideration the non-stationary character of the stochastic processes change ...
A. V. Nikitenko, M. O. Kostin
doaj
Predictive riccati control for enhancing power quality using extended pq theory in wind energy-based conversion systems. [PDF]
Sundari KT, Umamaheswari MG.
europepmc +1 more source

