Results 11 to 20 of about 9,701,700 (82)
Control of disturbing loads in residential and commercial buildings via geometric algebra. [PDF]
Many definitions have been formulated to represent nonactive power for distorted voltages and currents in electronic and electrical systems. Unfortunately, no single universally suitable representation has been accepted as a prototype for this power component.
Castilla MV.
europepmc +2 more sources
Non‐intrusive Load Monitoring Using Gramian Angular Field Color Encoding in Edge Computing
Non‐intrusive load monitoring (NILM) can infer the status of the appliances in operation and their energy consumption by analyzing the energy data collected from monitoring devices. With the rapid increase of electric loads in amount and type, the traditional way of uploading all energy data to cloud is facing enormous challenges.
Junfeng CHEN, Xue WANG
wiley +1 more source
Abstract The deployment of domestic smart metering infrastructure in Great Britain provides the opportunity for identification of home appliances utilising non‐intrusive load monitoring methods. Identifying the energy consumption of certain home appliances generates useful insights for the energy suppliers and for other bodies with a vested interest in
Ioannis Paraskevas +3 more
wiley +1 more source
Instantaneous active and reactive load signature applied in non‐intrusive load monitoring systems
Abstract The performance of non‐intrusive load monitoring (NILM) systems heavily depends on the uniqueness of the load signature extracted from the electrical appliances. Different load signatures have been proposed. Recently, in particular, v–i trajectory feature extraction is attracting more and more attention due to its unique characteristics ...
Ricardo Brito +5 more
wiley +1 more source
1996 Wholesale Power and Transmission Rate Schedules. [PDF]
Bonneville Power Administration`s (BPA) 1996 Wholesale Power Rate Schedules, 1996 Ancillary Products and Services Rate Schedule, 1996 Transmission Rate Schedules, and General Rate Schedule Provisions, contained herein, were approved on an interim basis ...
United States. Bonneville Power Administration.
core +1 more source
The increasing aggregation of renewable‐based distributed generating units besides the impressive growing usage of non‐linear loads raises unwanted challenges for traditional power terms definition in power engineering. This fact consequently affected the performance of the conventional control frameworks and industrial compensation techniques. In this
Marcelo Godoy Simões +2 more
wiley +1 more source
Integration of solar PV as a distributed generator (DG) require efficient and coordinated control measures for the proper synchronization. In this paper, a hybrid control algorithm for single stage solar photovoltaic (PV) system integrated with low voltage (LV)/medium voltage (MV) grid is proposed.
Priyanka Chaudhary, Mohammad Rizwan
wiley +1 more source
Mitigation of harmonic current for balanced three-phase power system based on Extended Fryze Adaptive notch filter [PDF]
The power quality problem, especially regarding harmonics contamination, has dramatically affected the overall power system stability. In response to this, using an Active Power Filter (APF) is considered one of the compelling methods to overcome ...
Mohd Radzi, Mohd Amran +4 more
core +2 more sources
Design and Optimisation of a Simple Filter Group for Reactive Power Distribution
Basic methods are presented to design a simple filter group and a method of shaping the resultant of the filter group’s impedance characteristics (distribution of the characteristics’ extremes) and then project equations were transformed into a uniform, common form that addresses issues of the reactive power distribution between component filters.
Ryszard Klempka, Riccardo Caponetto
wiley +1 more source
Living and Working Safely Around High-Voltage Power Lines. [PDF]
High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them.
United States. Bonneville Power Administration.
core +1 more source