Results 231 to 240 of about 65,160 (264)
Some of the next articles are maybe not open access.
Measurement of Carbon Concentration in Polycrystalline Silicon Using FTIR
Journal of The Electrochemical Society, 1991The carbon concentration in polycrystalline silicon produced via the Siemens process, the hydrogen reduction of trichlorosilane, was evaluated using FTIR. Samples measured included: as grown polycrystalline silicon, high-temperature annealed polycrystalline silicon, and float zone refined single-crystalline silicon.
Lydia L. Hwang +2 more
openaire +1 more source
Matrix measurements of high temperature molecules by FTIR
Journal of Molecular Structure, 1980Abstract Diatomic high temperature molecules are produced by reactions of metal vapor / metal chloride with active nitrogen. The molecules are isolated in a rare gas matrix at 10 K and measured by FTIR. The nitrenes are compared and the new molecules BiN (ω = 737 cm −1 ), LiN (ω=660 cm −1 ) and Tin (ω = 1037 cm −1 ) discussed.
openaire +1 more source
Ground-based FTIR Measurements with High Temporal Resolution
Journal of Atmospheric Chemistry, 1998We outline how ground-based Fourier transform infrared (FTIR) measurements of stratospheric trace species, obtained with high temporal resolution, could be used to detect filaments of polar vortex air at mid-latitudes and therefore test high spatial resolution chemical transport models (CTMs). Vertical column abundances of HCl, ClONO2, HNO3, N2O and HF
W. Bell +5 more
openaire +1 more source
In situ FTIR measurements of polyaniline in the non-metallic phase
Synthetic Metals, 1989Abstract This paper presents results of in situ FTIR measurements during cyclovoltammetric experiments of PANI in pH=4−5 electrolyte. Between −0.2 and +0.8 V vs. SCE only one oxidation-reduction peak is observed. Infrared spectra were recorded simultaneously during the potential sweep.
H. Neugebauer +3 more
openaire +1 more source
[In situ measurement of the permeability of concrete by FTIR-MIR].
Guang pu xue yu guang pu fen xi = Guang pu, 2015Fourier transform infrared spectroscopy with multiple internal reflection mode (FTIR-MIR) has been applied for the first time to measure the permeability of concrete. The effect of water-cement ratio and curing time on the microstructure and permeability of concrete was studied.
Lin Jun-ren +3 more
openaire +2 more sources
Basics of FTIR Spectroscopy and Measurement Techniques
Journal of The Adhesion Society of Japan, 2022openaire +1 more source
Dispersive Vs Ftir Photometric Accuracy - Can it Be Measured?
1987ABSTRACT The rotating-sector primary standard, used for determining photometric accuracy of dispersive infrared spectrometers, cannot be used for FTIR instruments; in fact we know of no primary standard of photometric accuracy usable with an FTIR spectrometer. The use of secondary standards, calibrated on dispersive instruments, has been described by
openaire +1 more source
Measurement of Nd:Y2O3 broad band near infra-red transmittance using FTIR system
Optical Materials, 2023Young-Jo Park +2 more
exaly
Features of Fourier Transform Infrared Spectroscopy (FTIR) measurement
Акустооптические и радиолокационные методы измерений и обработки информации. труды Российского научно-технического общества радиотехники, электроники и связи имени А.С. Попова : материалы 14-й Международной научно-технической конференции. XIV, 2021V.A. Vaguine, D.Yu. Ryzhkova
openaire +1 more source
Effect of plant sample preparation and measuring methods on ATR-FTIR spectra results
Environmental and Experimental Botany, 2020, Tomasz Durak
exaly