Results 21 to 30 of about 25,193 (285)
ObjectiveThis work aims to use machine learning models to predict gamma passing rate of portal dosimetry quality assurance with log file derived features.
Kah Seng Lew +6 more
doaj +1 more source
The Effect of Total Fields' Area and Dose Distribution in Step and Shoot IMRT on Gamma Passing Rate Using OCTAVIUS 4D-1500 Detector Phantom [PDF]
Introduction: Quality assurance is necessary for every IMRT plan.Octavius 4D-1500 detector phantom is one of the new phantoms for determining the treatment plan quality. This study aimed to examine the IMRT plans using the Octavius 4D-1500 to ...
Abdulrahman Abdulbaqi +5 more
doaj +1 more source
Background: Intensity-modulated radiation therapy (IMRT) may have too many peaks and valleys, making the treatment plan undeliverable. When there are too many fluency differences between adjacent pixels in the X or Y directions, the X and Y smoothing ...
Dinesh Kumar Saroj +2 more
doaj +1 more source
Dosimetric Comparison between Dynamic Wave Arc and Co-Planar Volumetric Modulated Radiotherapy for Locally Advanced Pancreatic Cancer [PDF]
Introduction: Dose reduction to the duodenum is important to decrease gastrointestinal toxicities in patients with locally advanced pancreatic cancer (LAPC) treated with definitive chemoradiotherapy.
Alshaymaa Abdelghaffar +11 more
doaj +1 more source
Purpose: To investigate a novel gamma analysis system for dose verification results in terms of clinical significance. Methods and Materials: The modified scheme redefined the computational domain of the conventional gamma analysis with the projections ...
Yiling Wang +5 more
doaj +1 more source
Predicting Gamma Passing Rates for Portal Dosimetry-Based IMRT QA Using Deep Learning [PDF]
Purpose/Objective(s) To assess if portal dosimetry-based IMRT QA gamma passing rates can be predicted with a Convolutional Neural Network (CNN) Model trained directly on the fluence maps without any domain expert knowledge. Materials/Methods A total of 4268 beams were collected from various treatment site plans and analyzed using gamma criteria of
D.M. Fondevila +3 more
openaire +1 more source
Evaluation of Delta Anatomy in 3D Patient-Specific IMRT Quality Assurance
Purpose: To evaluate the performance of Delta 4DVH Anatomy in patient-specific intensity-modulated radiotherapy quality assurance. Materials and Methods: Dose comparisons were performed between Anatomy doses calculated with treatment plan dose measured ...
Du Tang PhD +3 more
doaj +1 more source
Objective This study compared the dose verification results between plans created based on computed tomography (CT) scan and digital virtual phantom. Methods We retrospectively analyzed the treatment plan of 10 patients with head and neck cancer.
Ting‐Ting Liu +5 more
doaj +1 more source
Delivery quality assurance (DQA) is the process of establishing a treatment plan and verifying that the pre-treatment dose is delivered without any problems through a simulation.
Kang, YN +8 more
core +1 more source
Clinical performance of FractionLab in patient-specific quality assurance for intensity-modulated radiotherapy: a retrospective study [PDF]
Background This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device.
Se An Oh +4 more
doaj +1 more source