Results 41 to 50 of about 4,686 (224)

Evaluation of SF6 leakage from gas insulated equipment on electricity networks in Great Britain [PDF]

open access: yes, 2018
This paper examines the data collected from the power industry over the last six years of actual reported emissions of sulphur hexafluoride (SF6) and the potential impact.
Haddad, Abderrahmane, Widger, Phillip
core   +2 more sources

800 kV Fast Circuit Breaker: Mechanical Coupling Modelling, Buffer Design and Development

open access: yesHigh Voltage, EarlyView.
ABSTRACT The 800 kV fast circuit breaker (CB) used in ultra‐high voltage (UHV) converter transformer can reduce the total breaking time to 25 ms. It significantly improves the action speed and breaking capacity of the CB, with promising broad application prospects.
Enyuan Dong   +6 more
wiley   +1 more source

Investigation of Gas-Sensing Property of Acid-Deposited Polyaniline Thin-Film Sensors for Detecting H2S and SO2

open access: yesSensors, 2016
Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further.
Xingchen Dong   +4 more
doaj   +1 more source

Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects

open access: yesHigh Voltage, Volume 11, Issue 2, Page 317-344, April 2026.
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi   +3 more
wiley   +1 more source

Numerical simulation on fault arc characteristics of medium voltage air medium switchgear [PDF]

open access: yesAIP Advances
Based on magnetohydrodynamic theory, this paper establishes a two-dimensional axisymmetric model of a fault arc inside an enclosed medium-voltage (MV) air-insulated switchgear.
Lijun Wang   +9 more
doaj   +1 more source

Anomaly Detection for Partial Discharge in Gas-Insulated Switchgears Using Autoencoder

open access: yesIEEE Access, 2020
In this article, we propose a new anomaly detection method to detect the partial discharge in a gas-insulated switchgear. An autoencoder was used for anomaly detection and was modeled on the one-class classification problem.
Ngoc-Diem Tran Thi   +4 more
doaj   +1 more source

The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]

open access: yes, 2009
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Given, M.J.   +6 more
core  

Status Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance [PDF]

open access: yes, 2017
Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment.
Abdul-Malek, Zulkurnain   +2 more
core   +2 more sources

Research on Power Frequency Insulation Properties and Configurations of CF3SO2F Gas Mixture for Industrial Applications

open access: yesHigh Voltage, Volume 11, Issue 2, Page 556-563, April 2026.
ABSTRACT The breakdown characteristics of the novel eco‐friendly insulating gas CF3SO2F are fundamental to the design of gas‐insulated equipment. In this paper, the gas mixture parameters for CF3SO2F were optimised for different ambient temperatures in order to ascertain the insulation performance and liquefaction temperature constraints.
Shubo Ren   +5 more
wiley   +1 more source

Regional Court in Brno on Cartels in 2012. Case comments to judgments in CRT cartel and GIS cartel [PDF]

open access: yesYearbook of Antitrust and Regulatory Studies, 2013
In 2012, the Regional Court in Brno has delivered a couple of judgements in two globally notorious cases which were primarily dealt with by the European Commission: the gas insulated switchgear cartel (GIS cartel) and the cathode ray tubes cartel (CRT ...
Petra Joanna Pipková
doaj  

Home - About - Disclaimer - Privacy