Results 61 to 70 of about 4,686 (224)
Breakdown Voltage Using Bond Energy Calculation for CF3CHCl2/CO2 Mixture as Insulation Applied
— Sulfur hexafluoride gas according to the Montreal Protocol and Kyoto protocol needs to be limited and gradually reduced because it causes global warming, the greenhouse effect and acid rain on the environment.
Tedy Juliandhy
doaj
Surface Flashover in 50 Years: III. Extreme Environments and Industrial Challenges
ABSTRACT Modern high‐voltage electrical equipment operates in complex environments where surface conditions are subjected to multifaceted influences from electric fields, thermal gradients, contaminants, irradiation and other extreme environmental factors.
Zhen Li +6 more
wiley +1 more source
Analysis of By-Products of N2-SF6 Gas Mixtures Sparked under Inhomogenous Field Conditions [PDF]
A vast data on formation of by-products due to arc and spark decomposition of SF6 is available in literature [1–10]. But experimental work relating to N2 - SF6 gas mixtures is limited. In view of increasing application of gas mixtures, it is essential to
Dwarakanath, K. +2 more
core +4 more sources
Application of Sensors and Digitalization Based on IEC 61850 in Medium Voltage Networks and Switchgears [PDF]
Vzduchem izolované vysokonapěťové rozváděče jsou nedílnou součástí energetického distribučního řetězce a to jak v průmyslovém, tak ve veřejném sektoru. Hlavní funkcí rozváděče je ochrana pracovního personálu, rozpojování/odpojování a spínání, izolování ...
Štefanka, Martin
core
HVDC Submarine Power Cables in the World: State-of-the-Art Knowledge [PDF]
This report is the first deliverable of the OTG ("Offshore Transnational Grid") Work Package (2015-2016), which is intended to identify and analyse the engineering and geopolitical challenges for realising a transcontinental energy interconnection ...
ARDELEAN MIRCEA, MINNEBO PHILIP
core +1 more source
Life and reliability models, potentially able to account for any type of stress, even time varying, are developed and their integration in a digital twin is discussed. Algorithms for the dynamic assessment of insulation health condition through diagnostic testing or monitoring, are developed.
Gian Carlo Montanari +2 more
wiley +1 more source
Finite element analysis of reinforcement for gas insulated switchgear
Considering the burgeoning requirement for reinforcing gas-insulated metal-enclosed switchgear, a three-dimensional elastic-plastic finite element model was established to examine the stress distribution before and after reinforcement. The results showed that, under an internal pressure of 3.8 MPa, the maximum stress of the defective sample surpassed ...
Zhenning Huang +5 more
openaire +1 more source
A series resistive‐capacitive divider for harmonic voltage measurement of gas‐insulated switchgear was studied. It can step down the voltage while amplifying the proportion of harmonics in the total sensed voltage, thereby increasing the significant figure for the measurement and enabling the accurate measurement of high‐order, low‐amplitude harmonics.
Huizhong Pang +6 more
wiley +1 more source
Review of the decomposition characteristics of eco‐friendly insulation gas
As one of the major concerns of climate change, identifying a proper eco‐friendly insulation gas for replacing sulphur hexafluoride (SF6) becomes a prominent research topic in recent years.
Yuan Yang +5 more
doaj +1 more source
Stealthy Deception Attacks Against SCADA Systems
SCADA protocols for Industrial Control Systems (ICS) are vulnerable to network attacks such as session hijacking. Hence, research focuses on network anomaly detection based on meta--data (message sizes, timing, command sequence), or on the state values ...
A Kleinmann +12 more
core +1 more source