Pengaruh Keberadaan Partikel Asing Terhadap Karakteristik Medan Listrik Pada GIS Equilateral Tiga Fasa [PDF]
This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment.
Rizki Wahyu Pratama +2 more
doaj +3 more sources
AC breakdown and decomposition products detection characteristics of eco-friendly insulating medium in gas insulated switchgear [PDF]
Gas Insulated Switchgear (GIS) was a crucial electrical equipment that provides the safety and security of power systems, and finding the eco-friendly alternatives of sulphur hexafluoride (SF6) as insulating medium in GIS has been an urgent demand in ...
Shuai Du +5 more
doaj +2 more sources
Online Detection of Hydrogen Fluoride under Corona Discharge in Gas-Insulated Switchgear Based on Photoacoustic Spectroscopy [PDF]
Internal discharge and overheating faults in sulfur hexafluoride (SF6) gas-insulated electrical equipment will generate a series of characteristic gas products.
Liujie Wan, Xiaohe Zhao, Kang Li
doaj +2 more sources
Humid insulating gas (SF6) has been observed in a case study of 631 CB-bays of Gas Insulated Switchgear (GIS) operating under tropical conditions. The routine gas quality check in the case study reported that 20% of the non-Circuit Breaker enclosures have humidity above the value recommended by the IEEE and IEC standards.
A P Purnomoadi, J J Smit
exaly +4 more sources
This article contains the development of the Health Index (HI) and the Risk Assessment (RA) models for Gas Insulated Switchgear (GIS) operating under tropical conditions. A case study of 631 bays of GIS in tropics with service time from 1 up to 30 years is used during the development of the models. The basis for the HI model is the condition assessment
A P Purnomoadi, J J Smit
exaly +4 more sources
Finite-difference time-domain simulation of partial discharges in a gas insulated switchgear
It is important to estimate the current magnitude and charge amount of a partial discharge (PD) in a gas-insulated switchgear (GIS). In this study, electromagnetic fields generated by a PD in an 84 kV-class three-phase GIS for testing have been measured ...
Hiroki Tanaka +6 more
doaj +3 more sources
Distribusi Medan Listrik di Kompartemen Busbar Gas Insulated Switchgear (GIS) Menggunakan Charge Simulation Method [PDF]
Penelitian ini bertujuan untuk mengilustrasikan distribusi medan listrik di kompartemen busbar tipe gas insulated switchgear (GIS). Gas Insulated Substation (GIS) merupakan rangkaian peralatan gardu induk yang terpasang di dalam sebuah metal enclosure ...
Dewi, Riyani Prima, Rahmat, Saepul
core +3 more sources
Recurrent Neural Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear
The analysis of partial discharge (PD) signals has been identified as a standard diagnostic tool for monitoring the condition of different electrical apparatuses.
Minh-Tuan Nguyen +3 more
doaj +3 more sources
Evaluasi kualitas gas SF6 pada Gas insulated Switchgear setelah revitalisasi studi kasus pada PT. PLN (PERSERO) GIS Simpang [PDF]
Penelitian ini bertujuan mengevaluasi efektivitas revitalisasi pada Gas Insulated Switchgear (Gas Insulated Switchgear (GIS)) Simpang milik PT. PLN (Persero) dengan fokus pada kualitas gas SF6. Selain kemurnian, parameter lain seperti kadar air (moisture
Jamal, Mario
core +3 more sources
Extraction of Equivalent Circuit Parameter of the GIS Pipe Spacer [PDF]
In Gas Insulated Switchgear (GIS) substation, the spacer used for supporting conductor, isolating air chamber and insulation is a very important insulation component in GIS pipe, and it is important to study the spacer to ensure the insulation ...
Wang Yonghong +6 more
doaj +1 more source