AC breakdown and decomposition products detection characteristics of eco-friendly insulating medium in gas insulated switchgear [PDF]
Gas Insulated Switchgear (GIS) was a crucial electrical equipment that provides the safety and security of power systems, and finding the eco-friendly alternatives of sulphur hexafluoride (SF6) as insulating medium in GIS has been an urgent demand in ...
Shuai Du +5 more
doaj +3 more sources
Online Detection of Hydrogen Fluoride under Corona Discharge in Gas-Insulated Switchgear Based on Photoacoustic Spectroscopy [PDF]
Internal discharge and overheating faults in sulfur hexafluoride (SF6) gas-insulated electrical equipment will generate a series of characteristic gas products.
Liujie Wan, Xiaohe Zhao, Kang Li
doaj +3 more sources
Humid insulating gas (SF6) has been observed in a case study of 631 CB-bays of Gas Insulated Switchgear (GIS) operating under tropical conditions. The routine gas quality check in the case study reported that 20% of the non-Circuit Breaker enclosures have humidity above the value recommended by the IEEE and IEC standards.
A P Purnomoadi
exaly +5 more sources
This article contains the development of the Health Index (HI) and the Risk Assessment (RA) models for Gas Insulated Switchgear (GIS) operating under tropical conditions. A case study of 631 bays of GIS in tropics with service time from 1 up to 30 years is used during the development of the models. The basis for the HI model is the condition assessment
A P Purnomoadi
exaly +5 more sources
Finite-difference time-domain simulation of partial discharges in a gas insulated switchgear
It is important to estimate the current magnitude and charge amount of a partial discharge (PD) in a gas-insulated switchgear (GIS). In this study, electromagnetic fields generated by a PD in an 84 kV-class three-phase GIS for testing have been measured ...
Hiroki Tanaka +6 more
doaj +4 more sources
Recurrent Neural Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear
The analysis of partial discharge (PD) signals has been identified as a standard diagnostic tool for monitoring the condition of different electrical apparatuses.
Minh-Tuan Nguyen +3 more
doaj +4 more sources
This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment.
Rizki Wahyu Pratama +2 more
doaj +3 more sources
Penelitian ini bertujuan untuk mengilustrasikan distribusi medan listrik di kompartemen busbar tipe gas insulated switchgear (GIS). Gas Insulated Substation (GIS) merupakan rangkaian peralatan gardu induk yang terpasang di dalam sebuah metal enclosure dan diisolasi oleh gas bertekanan yaitu Sulfur Hexafluoride (SF6).
Saepul Rahmat, Riyani Prima Dewi
openaire +2 more sources
A Classification System for Insulation Defect Identification of Gas-Insulated Switchgear (GIS), Based on Voiceprint Recognition Technology [PDF]
Insulation defects that occur in gas-insulated switchgear (GIS), which is one of the most important types of equipment in the power grid, can lead to serious accidents. The ultrasonic detection method is commonly used to detect partial discharge (PD) signals in power equipment to discover defects.
Weijia Yao +4 more
openaire +3 more sources
To date, atmospheric concentrations of sulfur hexafluoride (SF6) are the most potent among the greenhouse gases identified by the Intergovernmental Panel on Climate Change (IPCC) and are still rising.
Pieter Billen +3 more
doaj +2 more sources