Results 1 to 10 of about 1,995,341 (213)

Replacing SF6 in Electrical Gas-Insulated Switchgear: Technological Alternatives and Potential Life Cycle Greenhouse Gas Savings in an EU-28 Perspective

open access: yesEnergies, 2020
To date, atmospheric concentrations of sulfur hexafluoride (SF6) are the most potent among the greenhouse gases identified by the Intergovernmental Panel on Climate Change (IPCC) and are still rising.
Pieter Billen   +3 more
doaj   +2 more sources

Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2 [PDF]

open access: yesEnergies, 2020
This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results
Phillip Widger   +5 more
doaj   +2 more sources

Pengaruh Keberadaan Partikel Asing Terhadap Karakteristik Medan Listrik Pada GIS Equilateral Tiga Fasa

open access: yesJurnal Nasional Teknik Elektro, 2021
This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment.
Rizki Wahyu Pratama   +2 more
doaj   +1 more source

SF6 Decomposed Component Analysis for Partial Discharge Diagnosis in GIS: A Review

open access: yesIEEE Access, 2022
This paper compiles, summarizes, and deliberates over one hundred important works on the different approaches and advances in the surveillance and diagnosis of the internal status of SF6 gas-insulated equipment (GIE), particularly partial discharge (PD ...
Ammar Salah Mahdi   +2 more
doaj   +1 more source

Recent Development of Two Alternative Gases to SF6 for High Voltage Electrical Power Applications

open access: yesEnergies, 2021
For many years, SF6 has been the preferred dielectric medium in electrical power applications, particularly in high voltage gas-insulated equipment. However, with the recognition that SF6 has an extremely long atmospheric lifetime and very high global ...
John Owens   +4 more
doaj   +1 more source

Design Review of Gas Insulated and Hybrid Gas Insulated Switchgear

open access: yesPower Research - A Journal of CPRI, 2022
This paper highlights overall process of design review, the challenges faced during the process and points observedto capture in revised technical specification. Also, it covers the advantage of adoption of this method by power utilityfor improving quality of product over the period.
Rashmi Chaudhary   +2 more
openaire   +1 more source

The impact of Particle on FGM insulator in a single phase gas insulated busduct on electric field stress

open access: yesJournal of Applied Science and Engineering, 2022
In the present day, technology, economics, and environmental sustainability have all combined to produce some very significant design problems for Gas-Insulated Substations (GIS).
A. Nagaraju   +2 more
doaj   +1 more source

Extraction of Equivalent Circuit Parameter of the GIS Pipe Spacer [PDF]

open access: yesE3S Web of Conferences, 2020
In Gas Insulated Switchgear (GIS) substation, the spacer used for supporting conductor, isolating air chamber and insulation is a very important insulation component in GIS pipe, and it is important to study the spacer to ensure the insulation ...
Wang Yonghong   +6 more
doaj   +1 more source

Overview of development, design, testing and application of compact gas-insulated DC systems up to ±550 kV

open access: yesGlobal Energy Interconnection, 2019
The development of high-voltage direct current gas-insulated switchgear assemblies (DC GIS) of rated voltages up to ±550 kV has been completed. DC GIS provide a compact technical solution with a high functional density, optimized for projects with ...
Maria Kosse   +3 more
doaj   +1 more source

Influence of Gas Insulated Switchgear Configuration Components on UHF PD Signals [PDF]

open access: yesJournal of Applied Research in Electrical Engineering, 2022
Partial Discharge (PD) measurement is one of the main methods for condition monitoring of Gas Insulated Switchgears (GIS). Internal Ultra High Frequency (UHF) sensors can be applied for capturing PD propagated electromagnetic signals within the GIS.
Reza Rostaminia   +2 more
doaj   +1 more source