Results 21 to 30 of about 1,995,341 (213)

Outdoor Insulation and Gas Insulated Switchgears

open access: yesEnergies, 2022
With the growth of the world’s population and faster-developing industries, larger amounts of electric energy are needed [...]
Issouf Fofana, Stephan Brettschneider
openaire   +5 more sources

UHF diagnostic monitoring techniques for power transformers [PDF]

open access: yes, 2004
This paper initially gives an introduction to ultra-high frequency (UHF) partial discharge monitoring techniques and their application to gas insulated substations.
Bennoch, C.J.   +3 more
core   +3 more sources

Status review on gas insulated switchgear partial discharge diagnostic technique for preventive maintenance [PDF]

open access: yes, 2017
Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment.
Ibrahim, V. M.   +2 more
core   +2 more sources

Analisis Gangguan Pada Sistem Gardu Listrik Berbasis Gas Insulated Switchgear 150 kV Dengan Metode High Voltage Test [PDF]

open access: yes, 2023
The insulator system in substations is essential in maintaining safety and efficiency in electricity transmission and distribution lines. The purpose of this research is to conduct High Voltage tests to check possible malfunctions in a gas-insulated ...
Bachri, Karel Octavianus   +2 more
core   +1 more source

Field Analysis of SF(6) Gas Insulated Cables and Its Application to Spacer Design [PDF]

open access: yes, 1974
This paper describes the spacer design for SF(6) gas insulated cables. The maximum electric stress within the cable is calculated by a numerical method, and it is recognized that the breakdown voltage depends linearly on the calculated values.
Yamamoto, Hideki   +2 more
core   +1 more source

The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]

open access: yes, 2009
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Timoshkin, I.   +6 more
core   +3 more sources

Influence of Conducting Particle on DC Flashover Characteristics and Tracking Property of GIS/GIL Insulator

open access: yesIEEE Access, 2022
Flashover at gas/insulator interface acts as a vital challenge to the safe and stable operation of gas-insulated system especially when involved with surface metallic particle.
Xiaolong Li, Chen Cao, Xin Lin
doaj   +1 more source

A Review of Research Progress on Environment-Friendly High-Voltage Power Switchgear

open access: yes工程科学与技术, 2023
Sulfur hexafluoride (SF6) is a potent greenhouse gas with a global warming potential index (GWP) of 23 900 times that of carbon dioxide and an atmospheric lifespan of 3 200 years. It is widely used in high-voltage switchgear.
Xiaolong HUANG   +4 more
doaj  

Correction to “Thermal Compatibility Between Perfluoroisobutyronitrile-CO2 Gas Mixture With Copper, Aluminum Switchgear”

open access: yesIEEE Access, 2019
In the above-named work, we explored the thermal compatibility between C4F7N-CO2 gas mixture with copper, aluminum used in gas insulated switchgear. The elemental composition of metal surface was investigated using the X-ray photoelectron spectroscopy ...
Yi Li   +7 more
doaj   +1 more source

Necessity of overvoltage protection studies for gas-insulated switchgear [PDF]

open access: yes, 2017
Kaasueristeisten kytkinlaitosten määrä kantaverkossa lisääntyy tulevaisuudessa merkittävästi erityisesti korvausrakentamisen myötä. Kaasueristeinen kojeisto on herkkä ylijännitteille ja aiheuttaa vikaantuessaan pitkän keskeytyksen sähkönsiirtoon sekä ...
Tammi, Veli Juhani
core   +1 more source

Home - About - Disclaimer - Privacy