This article contains the development of the Health Index (HI) and the Risk Assessment (RA) models for Gas Insulated Switchgear (GIS) operating under tropical conditions. A case study of 631 bays of GIS in tropics with service time from 1 up to 30 years is used during the development of the models. The basis for the HI model is the condition assessment
Purnomoadi, A.P. (author) +2 more
openaire +3 more sources
Synthesis of Graphene-Based Sensors and Application on Detecting SF6 Decomposing Products: A Review
Graphene-based materials have aroused enormous focus on a wide range of engineering fields because of their unique structure. One of the most promising applications is gas adsorption and sensing. In electrical engineering, graphene-based sensors are also
Xiaoxing Zhang, Hao Cui, Yingang Gui
doaj +1 more source
Research of GIS partial discharge type evaluation based on convolutional neural network
This paper presents a GIS (Gas Insulated Switchgear) partial discharge type evaluation based on the convolutional neural network. It is significant to study GIS partial discharge and effectively classify the types of GIS partial discharge.
Liuhuo Wang, Kang Hou, Lingqi Tan
doaj +1 more source
Quantification of the performance of iterative and non-iterative computational methods of locating partial discharges using RF measurement techniques [PDF]
Partial discharge (PD) is an electrical discharge phenomenon that occurs when the insulation materialof high voltage equipment is subjected to high electric field stress. Its occurrence can be an indication ofincipient failure within power equipment such
Alistair J. Reid +29 more
core +1 more source
A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C. +2 more
core +1 more source
Application of Optical Fiber Distributed Sensing System in Substation Maintenance
During daily operation of Substation, if Gas Insulated Switchgear (GIS)equipment breaks down, it will lead to the suspension of substation power supply, and national production and life cannot be guaranteed.
BAI Bin +5 more
doaj
Finite-difference time-domain simulation of partial discharges in a gas insulated switchgear
It is important to estimate the current magnitude and charge amount of a partial discharge (PD) in a gas-insulated switchgear (GIS). In this study, electromagnetic fields generated by a PD in an 84 kV-class three-phase GIS for testing have been measured ...
Hiroki Tanaka +6 more
doaj +1 more source
Synthesis of Hollow Nanofibers and Application on Detecting SF6 Decomposing Products
Hollow structured nanofibers have attracted much attention in diverse domains owing to their unique physicochemical properties and characteristics. Gas sensing is one of the most promising applications.
Zhaorui Lu +5 more
doaj +1 more source
AbstractGas‐insulated switchgears (GIS) are important equipment in electric‐supply stations where advanced techniques for safety and maintenance are required. As a result, a system is being developed that can automatically monitor and diagnose a GIS in service.This article focuses on some problems concerning insulating functions of GIS to discuss a ...
Hiroshi Inujima +2 more
openaire +2 more sources
Evaluation of SF6 leakage from gas insulated equipment on electricity networks in Great Britain [PDF]
This paper examines the data collected from the power industry over the last six years of actual reported emissions of sulphur hexafluoride (SF6) and the potential impact.
Haddad, Abderrahmane, Widger, Phillip