Accurate Harmonic Voltage Measurement Based on Series Resistive‐Capacitive Divider for Gas‐Insulated Switchgear

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
A series resistive‐capacitive divider for harmonic voltage measurement of gas‐insulated switchgear was studied. It can step down the voltage while amplifying the proportion of harmonics in the total sensed voltage, thereby increasing the significant figure for the measurement and enabling the accurate measurement of high‐order, low‐amplitude harmonics.
Huizhong Pang   +6 more
wiley   +1 more source

Stress Measurements of GIS Epoxy Composite with Transverse Waves Based on the Ultrasonic Pulse-Echo Method

open access: yesApplied Sciences, 2023
The mechanical reliability of the gas-insulated metal-enclosed switchgear (GIS) is critical to the safe and stable operation of a power system. The internal stress induced in GIS insulators, which typically lead to cracking, can degrade the mechanical ...
Zhouyiao Zou   +9 more
doaj   +1 more source

Comparison of Suppression Effects of Various Coating Schemes on Surface Charge Accumulation for DC GIS Insulator

open access: yesIET Science, Measurement &Technology, Volume 20, Issue 1, January/December 2026.
This work reports the performance of various coating schemes in suppressing charge accumulation on DC gas‐insulated switchgear (GIS) insulators. Coatings with different conductivities were deposited on the insulator in two schemes: single‐coating and zoning‐coating schemes.
Di Lu   +4 more
wiley   +1 more source

Research Status of Substation Vulnerability Under the Coupling Effect of Earthquake and Strong Wind

open access: yesAdvances in Civil Engineering, Volume 2026, Issue 1, 2026.
With the progressive advancement of China’s power industry toward higher voltage levels and larger capacity, substations have become critical infrastructures whose resilience to natural disasters requires urgent enhancement. In particular, under the coupled effects of multiple hazards such as earthquakes and strong winds, the optimization of substation
Yihua Gao   +5 more
wiley   +1 more source

Particle detector for gas insulated switchgear and the effect on environment

open access: yes, 2013
High voltage Gas Insulated Switchgear (GIS) is prone to metallic particles. The particle void can reduce the dielectric strength of the insulation material of SF6 gas.
Agos, M. F.   +2 more
core   +1 more source

PERANCANGAN GEDUNG GARDU INDUK GAS INSULATED SWITCHGEAR 150 KV JAKARTA TIMUR [PDF]

open access: yes, 2020
GIS (Gas Insulated Switchgear) adalah sebuah system penghubung dan pemutusJaringan listrik yang dikemas dalam sebuah tabung non ferro dan menggunakan bahan gas sulphumexaflouride (SF6) sebagai media isolasinya.Salah satunya adalah Gis kebon sirih II 150 ...
Andryansyah, -, Destoni, Deri
core  

Detection of Transient Decomposition Products of CF3SO2F and C4F7N via OES Under Spark and Glow Discharges

open access: yesHigh Voltage, Volume 10, Issue 6, Page 1582-1592, December 2025.
ABSTRACT The optical emission spectra (OES) reflect the presence of excited states in the gaseous discharge, which are directly linked to the decomposition characteristics of insulating gases. In this study, a pin/rod–plate discharge reactor driven by either a high‐voltage direct current (DC) generator or a pulsed generator was developed to establish ...
Chenxi Man   +5 more
wiley   +1 more source

Partial Discharge Detection Method of Fibre‐Composed HVDC Submarine Cable Based on φ‐OTDR and Hilbert Demodulation

open access: yesHigh Voltage, Volume 10, Issue 6, Page 1380-1389, December 2025.
ABSTRACT Partial discharge (PD) is the indicator of the insulation defect in cables. However, the pulse current method, which is widely adopted in land cables, cannot obtain PD signals of high‐voltage direct current (HVDC) submarine cables due to attenuation and installation position.
Hang Wang   +7 more
wiley   +1 more source

GSLI‐RTMdet: An automatic nondestructive detection method for internal defects in gas‐insulated switchgear X‐DR images

open access: yesHigh Voltage, Volume 10, Issue 4, Page 890-902, August 2025.
Abstract Accurately identifying the location and type of internal defects in gas‐insulated switchgear (GIS) is a challenge. To address this challenge, this study proposes a novel method for the nondestructive detection of GIS internal defects. This method is based on x‐ray digital radiography (X‐DR) technology and an improved real‐time models for ...
Guote Liu   +3 more
wiley   +1 more source

Testing and commisioning of GIS switchgear for high voltage substation / Mohd Zulkifli Mat Ghani [PDF]

open access: yes, 2003
This project presents a testing and commissioning of high voltage substation. The project focus on Gas Insulated Switchgear (GIS) is come out and the result of testing obtained are compared with Air Insulated Switchgear (AIS).
Mat Ghani, Mohd Zulkifli
core  