Partial Discharge Measurements in a High Voltage Gas Insulated Transmission Line Insulated with CO2 [PDF]
This paper uses practical experimentation to analyse the effect of replacing SF6 with pure CO2 in conventional gas insulated transmission line sections by studying partial discharge measurements taken with applied voltages up to 242 kV (rms). The results
Phillip Widger +5 more
doaj +4 more sources
Development of HVDC Gas-Insulated Components for the Power Supply of Neutral Beam Injectors [PDF]
The development of High Voltage Direct Current Gas-Insulated components that will be employed for the power supply of Neutral Beam Injectors, requires specific numerical tools to analyze the electric field distribution, with the purpose of supporting the
Francesco Lucchini, Nicolo Marconato
doaj +2 more sources
Determination of the Operating Temperature of the Gas-Insulated Transmission Line [PDF]
Gas-insulated lines (GILs) have been increasingly used as high-current busducts for high-power transmission. Temperature is one of the most important factors affecting the performance and ampacity of GILs. In this paper, an analytical method was proposed
Tomasz Szczegielniak +2 more
doaj +2 more sources
A Comparison of Partial Discharge Sensors for Natural Gas Insulated High Voltage Equipment [PDF]
The research in this paper consists of practical experimentation on a gas insulated section of high voltage equipment filled with carbon dioxide and technical air as a direct replacement to sulphur hexafluoride (SF6) and analyses the results of PD ...
Phillip Widger +3 more
doaj +2 more sources
Motion of metallic particle near the conical insulator of UHVAC gas-insulated transmission line
The UHV gas-insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability, and environmental friendliness.
Gang Sun +4 more
doaj +2 more sources
CLOSE-RANGE PHOTOGRAMMETRY METHOD FOR SF6 GAS INSULATED LINE (GIL) DEFORMATION MONITORING [PDF]
Close-Range Photogrammetry (CRP) technology advanced rapidly along with the development of camera sensors. CRP has many advantages over other methods in terms of technical data acquisition, product quality, and cost.
K. N. Fauzan +4 more
doaj +1 more source
The calculation method of the equivalent impedance and admittance parameters of the Gas Insulated Line (the Gas Insulated Line is abbreviated as GIL in this paper) grounded by the copper bar is studied and proposed.
Botong Li +4 more
doaj +1 more source
Finite Element Analysis and Experimental Study of Metal Shell of GIL [PDF]
Mathematical modeling, finite element numerical simulation and experimental measurement of the stress-deformation distribution of the gas-insulated metal-enclosed transmission line shell were carried out.
Mimi Gong +9 more
doaj +1 more source
A Review of UHV AC GIL Ex-factory Test Technology
Based on the application of UHV gas-insulated metal-enclosed transmission line(GIL)in the Sutong GIL Utility Tunnel Project, this paper firstly introduces the structural characteristics of UHV GIL, and analyzes its main technical parameters, type test ...
Shuang CHEN +6 more
doaj +1 more source
Green Gas for Grid as an Eco-Friendly Alternative Insulation Gas to SF6: A Review
This paper deals with a review of the state-of-the-art performance investigations of green gas for grid (g3) gas, which is an emerging eco-friendly alternative insulation gas for sulfur hexafluoride (SF6) that will be used in gas-insulated power ...
Baofeng Pan +5 more
doaj +1 more source

