Results 1 to 10 of about 65 (63)
Development and Experimental Research of VFTO Measuring Sensor [PDF]
Very fast transient overvoltage (VFTO) generated by an operating disconnector is one of the main reasons for electromagnetic disturbance in gas-insulated switchgear (GIS) substations.
Zihan Teng +4 more
doaj +2 more sources
Nonlinear modeling of magnetic materials for circuit simulations [PDF]
Magnetic materials in the form of magnetic rings are widely used in power engineering products. In many cases, they operate in high frequency and in nonlinear conditions, e.g., as damping elements in electrical power substations equipped with Gas ...
Kamil Kutorasiński +3 more
doaj +2 more sources
In the present day, technology, economics, and environmental sustainability have all combined to produce some very significant design problems for Gas-Insulated Substations (GIS).
A. Nagaraju +2 more
doaj +1 more source
The construction of transformer substations in transmission lines is a systematic, technical, and complex project with the need for numerous materials and resources. Under the development of the green economy, the requirements for energy conservation and
Xigang Liu +8 more
doaj +1 more source
Assessment of very fast transient overvoltage (VFTO) requires good knowledge of the behavior of gas-insulated substation when subjected to very high frequencies.
Muresan Alexandru +4 more
doaj +1 more source
The process of building and modernizing the high voltage substations generate the problems concerning the determination of the optimal technological solutions, which should be friendly to the environment, meet the criteria of sustainable development and ...
Pawel Rozga +4 more
doaj +1 more source
Partial Discharge Detection and Defect Location Method in GIS Cable Terminal
The complex structure of gas-insulated switchgear (GIS) cable terminals leads to serious electric field concentration, which is a frequent fault position of a high-voltage cable system. At present, due to the differences in the frequency bands of sensors,
Songyuan Li +9 more
doaj +1 more source
Switching operations in gas-insulated switchgear (GIS) substations generate transient electromagnetic fields in the GIS pipes. These fields leak out discontinuities of the GIS and induce electromagnetic disturbance voltages on the cables and ports of ...
Heng-Tian Wu +4 more
doaj +1 more source
Breakdown Mechanism of Different Sulphur Hexafluoride Gas Mixtures
Sulphur hexafluoride (SF6) gas and SF6 gas mixtures are widely used in gas-insulated systems (GIS) because they have good dielectric and thermal properties.
E. Onal
doaj +1 more source
Increased power demand and energy density in cities resulted in the establishment of Gas insulated systems (GIS) as a substitute for the conventional air-insulated substations.
Jagadeesh Adari +2 more
doaj +1 more source

