Results 121 to 130 of about 293 (157)

Design and Development of a Bio-Inspired UHF Sensor for Partial Discharge Detection in Power Transformers. [PDF]

open access: yesSensors (Basel), 2019
Nobrega LAMM   +5 more
europepmc   +1 more source

Comparison Between Suppressing Approaches of Very Fast Transients in Gas-Insulated Substations (GIS)

open access: yesIEEE Transactions on Power Delivery, 2013
In this paper, first transient waves in the gas-insulated substation (GIS) are analyzed and methods for suppression of very fast transients (VFTs) in GISs are introduced. For suppressing VFTs, four methods are presented, including suppression by terminal components, capacitance components, adopting a resistor-fitted disconnector, and ferromagnetic ...
H Nouri, Michael Negnevitsky
exaly   +4 more sources
Some of the next articles are maybe not open access.

Related searches:

Partial discharge in Gas Insulated substations (GIS): A development and engineering perspective

2013 12th International Conference on Environment and Electrical Engineering, 2013
GIS and its allied subsystems are always expected to function and work with extremely high level of reliability. These substations contain several dielectric interfaces and combinational insulating medias. The GIS may be subject to Partial discharge activity may initiate in some conditions in the GIS modules considering its varied operating conditions ...
V. Aaradhi, K. Gaidhani
exaly   +2 more sources

Study of the Grounding Behavior of Gas-Insulated Switchgear (GIS-Type Substations) Submitted to Lightning

2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe), 2023
Diego Mizette Olíz   +2 more
exaly   +2 more sources

State of the art in insulation of gas insulated substations: main issues, achievements, and trends

open access: yesIEEE Electrical Insulation Magazine, 2016
Nowadays power delivery grids face many challenges, among which are (1) steady growth of urban and suburban areas and the consequent reduction of space available for power facilities, (2) quest for higher power quality and availability, and (3) growing ...
G Mazzanti
exaly   +2 more sources

Magnetic and electric antennas calibration for partial discharge charge estimation in gas-insulated substations [PDF]

open access: yesInternational Journal of Electrical Power and Energy Systems, 2022
There are no accepted procedures that quantify the apparent charge of partial discharge (PD) in gas-insulated substations (GIS). This paper proposes a calibration method for PD charge estimation using unconventional electromagnetic sensors: a magnetic ...
Christian Mier, Armando Rodrigo Mor
exaly   +2 more sources

Approaches for Suppressing of Lightning Overvoltage in the Gas-Insulated Substation (GIS)

2010 Asia-Pacific Power and Energy Engineering Conference, 2010
Ali Parizad
exaly   +2 more sources

Home - About - Disclaimer - Privacy