Partial discharge in Gas Insulated substations (GIS): A development and engineering perspective
2013 12th International Conference on Environment and Electrical Engineering, 2013GIS and its allied subsystems are always expected to function and work with extremely high level of reliability. These substations contain several dielectric interfaces and combinational insulating medias. The GIS may be subject to Partial discharge activity may initiate in some conditions in the GIS modules considering its varied operating conditions ...
V. Aaradhi, K. Gaidhani
exaly +2 more sources
Comparison Between Suppressing Approaches of Very Fast Transients in Gas-Insulated Substations (GIS)
IEEE Transactions on Power Delivery, 2013In this paper, first transient waves in the gas-insulated substation (GIS) are analyzed and methods for suppression of very fast transients (VFTs) in GISs are introduced. For suppressing VFTs, four methods are presented, including suppression by terminal components, capacitance components, adopting a resistor-fitted disconnector, and ferromagnetic ...
Hassan Nouri, Michael Negnevitsky
exaly +2 more sources
2023 IEEE International Conference on Environment and Electrical Engineering and 2023 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe), 2023
DIEGO MIZETTE OLIZ +2 more
exaly +2 more sources
DIEGO MIZETTE OLIZ +2 more
exaly +2 more sources
Approaches for Suppressing of Lightning Overvoltage in the Gas-Insulated Substation (GIS)
2010 Asia-Pacific Power and Energy Engineering Conference, 2010Ahmad Tavakoli +2 more
exaly +2 more sources
2008 IEEE/PES Transmission and Distribution Conference and Exposition, 2006
Reliable and economical power transmission and distribution are key functions for the future electric power supply. Gas insulated switchgear is used in industrial areas to fulfil high-energy demands by space saving design with a minimum of cost. Only SF6 insulated switchgear is able to fulfil these requirements.
P. Bolin, H. Koch
openaire +1 more source
Reliable and economical power transmission and distribution are key functions for the future electric power supply. Gas insulated switchgear is used in industrial areas to fulfil high-energy demands by space saving design with a minimum of cost. Only SF6 insulated switchgear is able to fulfil these requirements.
P. Bolin, H. Koch
openaire +1 more source
Gas insulated substation (GIS) for HVDC
2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132), 2002The paper deals with the topic of a Gas Insulated Substation (GIS) optimized for HVDC. The electric field distribution of DC systems is mainly controlled by the conductivity k of the dielectric media. Surface charge accumulation leads to field distortion.
F. Messerer, W. Boeck
openaire +1 more source
Basic information on Gas Insulated Substation (GIS)
2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008This paper gives an overview about design of GIS, technologies, and worldwide experiences. The steps of technical development, stages of technical design, state of the art in the production, and quality insurance are explained with practical examples.
Phil Bolin, Hermann Koch
openaire +1 more source
Introduction and applications of GAS insulated substation (GIS)
IEEE Power Engineering Society General Meeting, 2005, 2005This tutorial is meant to present and teach about all the improvements done in the design of GIS technology and to report about the excellent experiences with GIS in other countries.
P. Bolin, H. Koch
openaire +1 more source
Exposure to electric and magnetic fields at 110 kV gas insulated substation (GIS)
IEEE/PES Transmission and Distribution Conference and Exhibition, 2003At Tampere University of Technology, the ELF electric and magnetic fields have been studied for several years. The studies have included measurements and calculations, as well as exposure assessments. In previous studies at TUT, electric and magnetic fields at 400 kV and 110 kV air insulated substations were measured.
T. Sauramaki +3 more
openaire +1 more source
Wavelet analysis used in UHF partial discharge detection in GIS [gas insulated substations]
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002One of the most important subjects in monitoring GIS is PD detection. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the experiments of detection PD in GIS using UHF technique is described. The results show that UHF method is effective in detecting PD in GIS and avoiding the disturbance of corona.
Z.M. Li +3 more
openaire +1 more source