Results 21 to 30 of about 127 (124)
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han +6 more
wiley +1 more source
Gas-insulated switchgear (GIS) serves as the core equipment in substations. Its partial discharge detection requires ultrasonic sensors to be precisely aligned with millimeter-level measurement points.
Yongchao Luo, Zifan Zhang, Yingxi Xie
doaj +1 more source
Calculation and protection on the lighting intruding waves of 550 kv GIS substation
Electromagnetic Transient Programme has been used to calculate the lightning intruding wave of 550 kV GIS substation. The effects of mode operation, surge impedance and length of cable have been considered in the process of calculation.
Dongpeng Sui +5 more
doaj +1 more source
This article proposes an integrated design method for a 12 kV intelligent ring main unit and constructs a fault diagnosis and isolation model. Firstly, building an integrated hardware platform can significantly improve perception speed and fusion potential.
Rongrong Shan, Jieyun Qiu, Dong Han
wiley +1 more source
Power Line Communication as a Sensor: Medium Voltage Cable Diagnostics
This article investigates the use of broadband power line (BPL) communication as a diagnostic tool for medium‐voltage cables. Experimental results show that BPL modem parameters change in the presence of partial discharges, enabling real‐time monitoring of insulation health and supporting predictive maintenance.
Lukas Benesl +6 more
wiley +1 more source
Environmental Effects of Electrically-Stressed Sulfur Hexafluoride
High Voltage (HV) equipment such as power switches, current or voltage transformers, and flexible HV transmission lines insulated by pressurized SF6 (or SF6/N2 mixtures) offer component compactness, high reliability and low maintenance demands compared ...
Palaiologopoulou Maria D. +2 more
doaj +1 more source
The electromagnetic effect study of GIS enclosure under high-frequency electromagnetic pulse
In gas insulated switchgear (GIS) substation, due to the operation of disconnect switch and circuit breaker, as well as short-circuit fault, SF6 will break down very rapidly.
Shu Chen +6 more
doaj +1 more source
Low‐probability but high‐impact events pose growing risks to power system security, particularly in renewable‐rich and highly digitalised electricity systems, affecting generation, networks, loads, and cyber‐communication layers. This paper reviews power system resilience issues and potentials, highlighting the role of meteorological factors, advanced ...
Jin Zhao, Xi Wang, Xuzhe Song, Yang Shen
wiley +1 more source
A series resistive‐capacitive divider for harmonic voltage measurement of gas‐insulated switchgear was studied. It can step down the voltage while amplifying the proportion of harmonics in the total sensed voltage, thereby increasing the significant figure for the measurement and enabling the accurate measurement of high‐order, low‐amplitude harmonics.
Huizhong Pang +6 more
wiley +1 more source
The reliable and efficient computational approach for the cable interference in gas insulated substations (GIS) is presented. The hybrid domain decomposition method-multilevel fast multi-pole algorithm (DDM-MLFMA) is presented herein.
Muhammad Bilal +5 more
doaj +1 more source