Results 101 to 110 of about 4,696 (224)
The reliability of GIS (gas-insulated switchgear) circuit breakers significantly depends on the condition of the insulated pull rods, with micro-defects on their surface posing a potential risk for micro-discharges and breakdown incidents. Experimentally
Shu Niu +8 more
doaj +1 more source
Time domain analysis of switching transient fields in high voltage substations [PDF]
Switching operations of circuit breakers and disconnect switches generate transient currents propagating along the substation busbars. At the moment of switching, the busbars temporarily acts as antennae radiating transient electromagnetic fields within ...
Judd, M.D., Musa, B.U., Siew, W.H.
core
Application of Innovative Transmission Technologies for the Development of the Future European Power System [PDF]
The present paper focuses on main technical, environmental, and economic features of three types of advanced transmission technologies, currently having a different level of maturity and deployment in Europe.
FULLI Gianluca +3 more
core
To study the surface flashover characteristics of single-phase basin-type insulators in gas insulated metal-enclosed switchgear (GIS) under low-frequency transmission, an electro-thermal-fluid coupling simulation is employed.
LI Guoqiang +6 more
doaj +1 more source
One-Shot Learning for Partial Discharge Diagnosis Using Ultra-High-Frequency Sensor in Gas-Insulated Switchgear. [PDF]
Tuyet-Doan VN +5 more
europepmc +1 more source
3D Printing Technique-Improved Phase-Sensitive OTDR for Breakdown Discharge Detection of Gas-Insulated Switchgear. [PDF]
Chen Z +9 more
europepmc +1 more source
Issues concerning centralized versus decentralized power deployment [PDF]
The results of a study of proposed lunar base architectures to identify issues concerning centralized and decentralized power system deployment options are presented.
Harty, Richard B. +2 more
core +1 more source
Studi Karakteristik Tegangan Tembus DC Polaritas Positif pada Gas Nitrogen (N2) [PDF]
Insulation of Sulfur hexafluoride (SF6) gas, nitrogen (N2) gas and Carbon Dioxide (CO2) gas usually used in circuit breaker. Sulfur hexafluoride (SF6) gas is widely used in high-voltage system.
Murdiya, F. '. (Fri) +1 more
core
Коммутационные испытания экспериментального вакуумного выключателя [PDF]
Актуальность работы обусловлена активно происходящим техническим перевооружением электрических сетей среднего класса напряжения на предприятиях нефтегазового комплекса Российской Федерации.
Кладько, Андрей Александрович +2 more
core
CARTELS – BETWEEN THEORY, LENIENCY POLICY AND FINES [PDF]
Among the anti-competitive practices sanctioned by competition law, cartel is the most harmful to the competitive environment. Cartel participation is sanctioned both by national and community legislation with large fines, which can reach up to 10% of ...
Berinde Mihai
core