Results 111 to 120 of about 4,696 (224)

MOD-0A 200 kW wind turbine generator design and analysis report [PDF]

open access: yes
The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments.
Anderson, T. S.   +6 more
core   +1 more source

Assessing the effects of power quality on partial discharge behaviour through machine learning [PDF]

open access: yes, 2010
Partial discharge (PD) is commonly used as an indicator of insulation health in high voltage equipment, but research has indicated that power quality, particularly harmonics, can strongly influence the discharge behaviour and the corresponding pattern ...
Bahadoorsingh, S.   +4 more
core  

Magnetohydrodynamics (MHD) Engineering Test Facility (ETF) 200 MWe power plant. Design Requirements Document (DRD) [PDF]

open access: yes
A description and the design requirements for the 200 MWe (nominal) net output MHD Engineering Test Facility (ETF) Conceptual Design, are presented. Performance requirements for the plant are identified and process conditions are indicated at interface ...
Bents, D. J.   +5 more
core   +1 more source

Investigating the characteristics of internal discharge shock waves in gas‐insulated switchgear under varied gap configurations

open access: yesIET Generation, Transmission & Distribution
Gas‐insulated switchgears (GIS) are crucial components of high‐voltage power transmission and distribution systems. Internal discharges within GIS have garnered significant attention in the field of power engineering.
Chenglong Jia   +3 more
doaj   +1 more source

Method for Sensing the Temperature Rise Rate of GIS Busbar Conductors Considering Transient Ambient Temperature

open access: yesIET Science, Measurement & Technology
Currently, the perception of temperature rise inside the gas insulated switchgear (GIS) is mainly achieved by fitting and training steady‐state temperature values, whereas abnormal temperature rise is a long and slow transient process, so there is a lack
Hangyu Cao   +5 more
doaj   +1 more source

SP-100 reactor with Brayton conversion for lunar surface applications [PDF]

open access: yes
Examined here is the potential for integrating Brayton-cycle power conversion with the SP-100 reactor for lunar surface power system applications. Two designs were characterized and modeled.
Hanlon, James C.   +4 more
core   +1 more source