Results 51 to 60 of about 1,373 (216)
Diagnóstico de descargas parciais em subestações isoladas a gás SF6 utilizando redes neurais artificiais [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia ElétricaO presente trabalho de dissertação aborda o desenvolvimento de uma ferramenta computacional para o diagnóstico de ...
Paulo, Assis Rogério Gomes da Silva
core
Study of Wireless Secondary Connections in Gas Insulated Switchgear
The paper first discusses the feasibility of the wireless communication in GIS (Gas Insulated Switchgear) substation. The signals inside GIS according to ISA100 standard are first classified and then a scheme to transmit some of the signals by ZigBee ...
Fu Sheng Wei +4 more
core +1 more source
Latent insulation defects introduced in manufacturing process of gas-insulated switchgears can lead to partial discharge during long-time operation, even to insulation fault if partial discharge develops further.
Xingchen Dong +4 more
doaj +1 more source
Anomaly Detection for Partial Discharge in Gas-Insulated Switchgears Using Autoencoder
In this article, we propose a new anomaly detection method to detect the partial discharge in a gas-insulated switchgear. An autoencoder was used for anomaly detection and was modeled on the one-class classification problem.
Ngoc-Diem Tran Thi +4 more
doaj +1 more source
Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi +3 more
wiley +1 more source
Chemical by-Product Diagnostic Technique for Gas Insulated Switchgear Condition Monitoring
Chemical by product diagnostic technique is an efficient, cost-effective and reliable diagnostic technique for gas insulate switchgear condition monitoring in view of its high sensitivity and anti- internal and external electromagnetic interference and ...
Abdul-Malek, Zulkurnain +2 more
core +1 more source
Numerical simulation on fault arc characteristics of medium voltage air medium switchgear [PDF]
Based on magnetohydrodynamic theory, this paper establishes a two-dimensional axisymmetric model of a fault arc inside an enclosed medium-voltage (MV) air-insulated switchgear.
Lijun Wang +9 more
doaj +1 more source
ABSTRACT The breakdown characteristics of the novel eco‐friendly insulating gas CF3SO2F are fundamental to the design of gas‐insulated equipment. In this paper, the gas mixture parameters for CF3SO2F were optimised for different ambient temperatures in order to ascertain the insulation performance and liquefaction temperature constraints.
Shubo Ren +5 more
wiley +1 more source
Regional Court in Brno on Cartels in 2012. Case comments to judgments in CRT cartel and GIS cartel [PDF]
In 2012, the Regional Court in Brno has delivered a couple of judgements in two globally notorious cases which were primarily dealt with by the European Commission: the gas insulated switchgear cartel (GIS cartel) and the cathode ray tubes cartel (CRT ...
Petra Joanna Pipková
doaj
A systematic study of a series of porous organic cages with perfluorinated alkyl side‐chains of different lengths is presented. The structure‐property relationship of the various cages on gas sorption of highly potent greenhouse gases, such as perfluorocarbons (PFCs), sulfur hexafluoride (SF6), and nitrogen trifluoride (NF3) is investigated.
Ke Tian +8 more
wiley +1 more source