Results 51 to 60 of about 4,696 (224)

Regional Court in Brno on Cartels in 2012. Case comments to judgments in CRT cartel and GIS cartel [PDF]

open access: yesYearbook of Antitrust and Regulatory Studies, 2013
In 2012, the Regional Court in Brno has delivered a couple of judgements in two globally notorious cases which were primarily dealt with by the European Commission: the gas insulated switchgear cartel (GIS cartel) and the cathode ray tubes cartel (CRT ...
Petra Joanna Pipková
doaj  

The suitability of N2 to replace SF6 in a triggered spark-gap switch for pulsed power applications [PDF]

open access: yes, 2009
The high dielectric strength of sulphur hexafluoride (SF6) when compared with other gases, coupled with safety benefits such as non-flammability and non-toxicity, has seen the widespread use of SF6 for the insulation of switching components. However, SF6
Given, M.J.   +6 more
core  

Status Review on Gas Insulated Switchgear Partial Discharge Diagnostic Technique for Preventive Maintenance [PDF]

open access: yes, 2017
Gas insulated switchgear (GIS) plays a vital role in high voltage transmission of electrical energy due to its advantages of high reliability and performance, compact in dimensions and outstanding compatibility with the environment.
Abdul-Malek, Zulkurnain   +2 more
core   +2 more sources

Highly Selective Adsorption of Fluorinated Gases by Porous Organic Cages – Effects of Fluorinated Side‐Chains

open access: yesAdvanced Materials, Volume 38, Issue 7, 2 February 2026.
A systematic study of a series of porous organic cages with perfluorinated alkyl side‐chains of different lengths is presented. The structure‐property relationship of the various cages on gas sorption of highly potent greenhouse gases, such as perfluorocarbons (PFCs), sulfur hexafluoride (SF6), and nitrogen trifluoride (NF3) is investigated.
Ke Tian   +8 more
wiley   +1 more source

Applying an analytical framework to production process improvement [PDF]

open access: yes, 2007
Thesis (M.B.A.)--Massachusetts Institute of Technology, Sloan School of Management; and, (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering; in conjunction with the Leaders for Manufacturing Program at MIT, 2007 ...
Underwood, Curtis J. (Curtis James)   +1 more
core  

Spectral Characteristics and Evolution Mechanism of Silicon Rubber Surface Discharge Under Thermal Ageing Condition

open access: yesHigh Voltage, Volume 11, Issue 1, Page 192-200, February 2026.
ABSTRACT Surface discharge is a typical fault type in electric power equipment. High temperature in long‐term operation can easily lead to ageing of materials, resulting in changes in surface characteristics and surface discharge faults. In this paper, a method of surface discharge identification of silicon rubber (SiR) based on spectral detection ...
Yanze Han   +6 more
wiley   +1 more source

Adsorption properties of Ni cluster modified TiO2 (1 0 1) towards SF6 decomposition gases

open access: yesHigh Voltage, 2023
Online detection of insulation defects the decomposition products of SF6 plays a key role in ensuring the safe operation of the gas‐insulated switchgear (GIS) equipment. The pristine TiO2 (1 0 1) modified by Ni cluster (1–3 Ni atoms) is used as a new gas‐
Yingang Gui   +3 more
doaj   +1 more source

A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]

open access: yes, 2010
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C.   +2 more
core   +1 more source

Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method

open access: yesHigh Voltage, Volume 11, Issue 1, Page 274-283, February 2026.
ABSTRACT Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS). This study proposes a nondestructive method to measure the residual stress on epoxy insulators using thermoelastic effects.
Hucheng Liang, Bei Chu, Boxue Du
wiley   +1 more source

Quantitative Evaluation of Mechanical Defects for Circuit Breakers Based on Self‐Adaptive Fault Feature Tracking

open access: yesHigh Voltage, Volume 11, Issue 1, Page 297-304, February 2026.
ABSTRACT Many researchers are committed to improving the diagnosis accuracy and solving the few‐shot problem on circuit breakers (CBs). However, the research on the vibration transmission mechanism of the fault is insufficient, which makes it difficult to find the potential design defects of CBs through vibration.
Jiayi Gong   +3 more
wiley   +1 more source